TROUBLESHOOTING

Trouble
No motor ignition
Insuffi cient dirty water vacuuming
Insuffi cient solution fl ow to the brush/pad
The squeegee leaves marks on the fl oor
For further information refer to the Service Manual, available at any Advance Service Center.

SCRAPPING

Have the machine scrapped by a qualifi ed scrapper.
Before scrapping the machine, remove and separate the following materials, which must be disposed of properly according to the
Law in force:
Brush
Pad
Electrical and electronic components (*)
(*)
Refer to the nearest Advance Center especially when scrapping electrical and electronic components.
20
INSTRUCTIONS FOR USE
The power supply cable (21) is faulty or
disconnected from the electrical mains
The recovery tank (26) is full
The vacuum grid (36) is clogged or the fl oat is
stuck closed
Vacuum hose (22) disconnected from the
squeegee (11) or faulty
The squeegee (11) is dirty or the squeegee
blades (13, 14) are worn or damaged
The recovery tank cover (6) is not properly
closed, or the gasket (32) is damaged
Dirty recovery tank (6) (clogged drain hole)
Dirty solution fi lter (20)
Debris under the squeegee blades (13, 14)
Worn, chipped or torn squeegee blades (13,
14)
909 5855 000(4)2009-11
Possible Cause
Micromatic™ M17E
Remedy
Replace the cable or connect it
Empty
Clean the grid and check the fl oat
Connect
Clean the squeegee or replace the blades
Check and/or clean the seating surface or
replace the gasket
Clean
Clean
Remove the debris
Replace the blades