Outlet Valve - Titan POWRLINER 4500 Mode D'emploi

Masquer les pouces Voir aussi pour POWRLINER 4500:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

REPAIRS
8.3

OUTLET VALVE

1. Use a 22 mm wrench to remove the outlet valve from the
paint section.
2. Carefully remove the clasp (Fig. 27, pos. 1) using a
screwdriver. The compression spring (2) presses ball (4)
and valve seat (5) out.
3. Clean or replace the components.
4. Check the O-ring (7) for damage.
5. Check the installation position when mounting the spring
support ring (3) (clipped onto spring (2)), outlet valve seat
(5) and seal (6), refer to figure.
6
5
4
3
2
7
1
26
PL4500

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

2407312407313

Table des Matières