TEChNiCAL dATA

Contol unit supply
Output supply
Power maximum motor
Output supply accessories
Protection level
Operating temp.
Radio receiver
Rolling code transmitters supported
Wire connections shown in Fig. 1 are described hereunder:
Terminal No.
Function
1-2
Power supply
3-4
Flashing light
4-5
Motor light
6-7-8
Motor 1/2
9
COM
10
SWO
11
SWC
12
STOP
13
PHOT
14
OPEN
15
CLOSE
16
Step-by-Step
17-18
24 Vac
19-20
AUX
21-22
COSTA
23-24
Aerial
CM-CM
Capacitor
J3
Radio receiver
Should two motors be used, connect the limit switches of one single motor to the control unit.
The connection between CP.ZEd230-E and the ZEd.SC card is shown in Fig.3.
F1
Output protection fuse of accessories and signals
F2
Motor protection fuse
The programming of the various functions of the control unit is carried out using the LCD display on the control unit and setting the
desired values in the programming menus described below.
The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer.
230 Vac 50/60 Hz or 115Vac 50/60Hz according to the version
1/2 motor 230Vac
300+300 W
24Vac 1Amax.
IP54
-20°C / +70°C
built in 433,92 MHz confgurabile (rolling-code or programmable + rolling-code)
64 rolling-code
CP.ZEd230-E CoNTRoL uNiT

WiRE diAGRAm

description
Input, 230VAC 50Hz (1-Phase/2-Neutral)
Connection of flashing light, 230Vac 40W max.
Connection to the courtesy light (230VAC 40+40W max.).
Connection to motor 1/2 : (6-speed/7-Com/8-speed)*
Should 2 motors be used, connect the second motor in parallel.
Common for limit switch and all control inputs.
Input, OPEN limit switch (N.C. contact)
Input, CLOSE limit switch (N.C. contact)
Input, STOP push button (N.C. contact)
Input, connection to safety devices, N.C. contact
(e.g. Photocells)
Input, OPEN push button (N.O. contact)
Input, CLOSE push button (N.O. contact)
Input, step-by-step push button (N.O. contact)
Output, power supply of accessories, 24Vac/1A max.
Normally Open (N.O.) contact, not powered, configurable as SCA/II°CH/PHOTO TEST.
Input, safety edge contact
Resistive edge: Closed "DAS" jumper
Mechanical edge: Open "DAS" jumper
If the safety edge is activated in the opening phase, the gate stops.
In the closing phase, the gate stops and the performs a movement reversion (opens) for 3s.
Connection to the radio receiver card of the aerial (23-screen/24-signal).
Connected to motor capacitor
Built-in radio receiver
imPoRTANT:
FuSES
PRoGRAmmiNG
13