ERR1: Error, photocells, presence of an obstacle or non-powered photocells.
If the transmitter code is already stored in the receiver, the remote radio learning can be carried out (without accessing the control
unit).
IMPORTANT: The procedure should be carried out with gate in the opening phase, during the TCA dwell time.
Proceed as follows:
1 Press the hidden key of the transmitter, the code of which has already been stored in memory.
2 Within 5 seconds, press the already memorised transmitter key corresponding to the channel to be matched to the new transmitter.
The flashing light switches on.
3 Within 10 seconds, press the hidden key of the new transmitter.
4 Within 5 seconds, press the key of the new transmitter to be matched to the channel selected at item 2. The flashing light switches
off.
5 The receiver stores the new transmitter code and exits from the programming mode immediately.
In the event of malfunctions, by pressing key + or - the status of all inputs (limit switches,
control and safety) can be displayed. One segment of the display is linked to each input.
In the event of failure it switches on according to the following scheme.
TECHNICAL DATA
Mains power supply
Output, Motor
Motor maximum power
Output, power supply of accessories
Protection level
Operating temperature
Radio receiver
No. of codes storable in memory
16
ERROR MESSAGES
TRANSMITTER REMOTE LEARNING
DIAGNOSTICS
230 VAC 50/60 Hz (115VAC 50/60 Hz for HEADY 115)
1/2 motor 230VAC (115V for HEADY 115)
500W + 500W
24VDC 500mA max.
IP54
-20°C / +70
C
°
433,92 MHz, incorporated and configurable
64
P.P.
PED
PHOT
STOP