The tables below describe the individual functions available in the control unit.
MENU
Automatic closing time. Active only with logic "TCA"=ON.
TCA
At the end of the set time the control unit orders a closing manoeuvre.
Motor 1 work time. Regulates the maximum duration of the opening and closing
TM1
manoeuvre of the motor 1.
It must be set about 4 sec. longer than the actual travel time of the automatism.
Motor 2 work time. Regulates the maximum duration of the opening and closing
TM2
manoeuvre of the motor 2.
It must be set about 4 sec. longer than the actual travel time of the automatism.
Mot.2 opening delay time.
TDMo
Regulates the delay time of motor 2 on opening with respect to motor 1
Mot.1 closing delay time
TDMC
Regulates the delay time of motor 1 on closing with respect to motor 2
Torque of Motor 1. The torque applied to motor 1 is adjusted.
COMPLY WITH REGULATIONS IN FORCE!
PM1
In oil-hydraulic motors, regulate unit to maximum value (99).
Use the by-pass valves to adjust the applied torque.
Torque, Motor 2. The torque applied to motor 2 is adjusted.
COMPLY WITH REGULATIONS IN FORCE!
PM2
In oil-hydraulic motors, regulate unit to maximum value (99).
Use the by-pass valves to adjust the applied torque.
The torque applied to motor 1 during braking in the opening and closing phase is
PS1
adjusted. COMPLY WITH REGULATIONS IN FORCE
The torque applied to motor 2 during braking in the opening and closing phase is
PS2
adjusted. COMPLY WITH REGULATIONS IN FORCE!
ELS/SRL contact activation time.
At the beginning of each single operation, the contact closes for the preset time.
TLS
If it is preset on 0, it has the service light function. The contact remains closed
when the motor is moving or is in TCA dwell time and it opens when the motor is
stopped.
MENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables condominium function.
Off: condominium function disabled.
IbL
On: condominium function enabled. The step-by-step impulse or transmitter
impulse has no effect during the opening phase.
Enables or disables rapid closing
On: rapid closing enabled. With the gate open or in the opening phase the
SCL
intervention of the photocell causes automatic closing after 3 s. Active only with
TCA:ON.
Off: rapid closing disabled.
Braking is enabled or disabled.
On: Braking activated. Braking starts around 7 seconds before the end of the op-
Sld
erating time preset with TM1/TM2 parameters.
Off: Braking excluded.
Selects the operating mode of the "Step by step button" and of the transmitter.
PP
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Enables or disables pre-blinking.
PRE
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.

PARAMETERS, LOGIC AND SPECIAL FUNCTIONS

PARAMETERS (PAR)
FUNCTION
LOGIC (LOG)
FUNCTION
MEMO
MIN-MAX-(Default)
1-240-(40s)
5-180-(24s)
5-180-(24s)
0-15-(2s)
0-40-(3s)
1-99-(40%)
1-99-(40%)
1-99-(70%)
1-99-(70%)
0-240-(90s)
MEMO
ON-OFF-(Default)
(ON)
(OFF)
(OFF)
(ON)
(OFF)
(OFF)