CAUTION!: The WAVE control unit is equipped with an embedded anti-crash device (amperometric sensor).
Given the overall dimensions of the door leaves for which the device is intended, the latter cannot be con-
sidered a safety device. It is therefore STRICTRLY MANDATORY to install activated protection sensitive
edges according to regulations in force.
N° Terminals
Function
T1-T2-T3
Power supply
5-6-7-8
INVERTER
9-10
Flashing light
24V Flashing
15-16
light or Phototest
17-18
SCA
19-20
24 VAC
SERIAL 485
Serial, inverter
21-22
Antenna
23-36
COM
24
SWC
25
SWO
26
PHOT 1
27
PHOT 2
28
PHOT 3
29
SWO-R
30
STOP
31
OPEN
32
CLOSE
33
PED
34
Step-by-Step
35
SWC-R
37-38
SAFETY
39-40
INVERTER
41-42
COVER
43-44
SAFETY
45-46
AUX OUT
Fuse
Type
F1
250V T1A
F2
250V T400mA
F3
250V T630mA
F4
500V T125mA
F5
250V T500mA
The control panel bypass pushbutton is located inside the control panel box, next to the inverter.
In case of control panel failure, by pushing this pushbutton it is possible to use UP/DOWN pushbuttons on the control panel cover in
hold to run mode.
In this mode the pushbutton must be kept pressed for the whole run, the operator must see the door moving, because all of the safety
inputs are excluded, as well as limit switches and slow down.
It must be used in case of emergency only, while waiting for a technical check up to recover control panel.
14
WAVE CONTROL UNIT

INPUT/OUTPUT FUNCTIONS

Description
Three-phase mains power supply.
The unit is powered through a mains filter applied before the control unit.
T1:L1 - T2:L2 - T3:L3 - 4:GND.
INVERTER connection
5:GND - 6:R - 7:S - 8:T.
Connection of flashing light, 230VAC 40W max.
In the WAVE that output is used to wire the electric brake.
Connection to 24VAC flashing light or Phototest output for checked photocells.
Normally open, voltage-fee contact for open gate indicator light, 24VAC 0.5A max
Output, power supply of accessories, 24Vac/400mA max
485 serial communication between control logics and Inverter.
Connection to built-in radio receiver module of the antenna (21-signal/22-monitor).
Common, for all control inputs.
Input, CLOSE limit switch (Normally Closed contact)
Input, OPEN limit switch (Normally Closed contact)
Input, Limit switch 1 (NC contact). It can be disconnected in the opening phase, see PH01 logics.
Input, Limit switch 2 (NC contact). It can be disconnected in the opening phase, see PH02 logics.
Input, Limit switch 3 (NC contact). It can be disconnected in the opening phase, see PH03 logics.
Beginning of opening slow down limit switch input (N.C. contact)
Input, STOP push-button (Normally Closed contact)
Input, push-button for OPEN contact (Normally Open contact)
Input, CLOSE push-button (Normally Open contact)
Input, push-button for pedestrian opening (Normally Open contact)
Input, Step-by-Step push-button (Normally Open contact)
Beginning of closing slow down limit switch input (N.C. contact)
Input, sensitive safety edge.
Safety edge of the resistive type: Jumper "DAS" closed.
Safety edge of the mechanical type: Jumper "DAS" open.
When the safety edge is activated, the door movement is stopped and reversed for around 3sec.
Safety connection provides control of the hardware emergency stop to the inverter. It is
always open with stopped motor, pressed SAFETY push-button .
Optional safety contact, not in use, do not remove the 41/42 bridge
NC safety switch (installed on the control panel box cover)
Auxiliary output, configurable through the AUX parameter.
Voltage-free contact, 250VAC 16A max.
Description
Protection, power supply of accessories
Protection, logics of board
Protection, common inputs and serial of inverter
Protection, transformer primary
Protection, lashing light, 230V
BYPASS PUSHBUTTON