Beninca WAVE Manuel page 17

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

tst3
As for TST1, but referred to PHOT3 input
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
CVAR
Off: Receiver enabled for rolling-code and programmable code transmitters (self-
learning and Dip Switch).
The remote storage of the radio transmitter codes is enabled or disabled (see par.
REMOTE LEARNING).
REM
On: Enabled remote storage
Off: Disabled remote storage.
Enable or disable the Hold to Run mode in closure
On: Hold to run mode
chtr
Opening works normally, whereas closure happens by keeping the CLOSE pushbut-
ton pressed
Off: automatic functioning
The lock function is enabled or disabled.
Off: Lock function disabled.
BLC
On: Lock function enabled. After the triggering of the closure limit switches, the
control unit delays the stop by approx. 0.5sec in order to allow a better resting of the
gate leaf onto the stoppers. DAS input is activated in the closing phase only.
MENU
By selecting this function, the receiver is waiting for (Push) a transmitter code to be assigned to the step-by-step
function.
PP
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
By selecting this function, the receiver is waiting for (Push) a transmitter code to be assigned to the second radio
channel.
2Ch
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
When this function is selected, the receiver awaits (Push) a transmitter code to be assigned to the PED function.
Press the transmitter key, which is to be assigned to this function.
PED
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
By selecting this function, the receiver is waiting for (Push) a transmitter code to be erased from memory.
CLR
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
RTR
The memory of the receiver is entirely erased. Confirmation for the operation is asked.
The number of cycles (open+close) completed by the system is displayed.
When the push-button <PG> is pressed once, the first 4 digits are displayed, if the push-button is pressed once more, the last 4
digits are displayed.
E.g. <PG> 0012 >>> <PG> 3456: 123.456 cycles were performed.
This function allows to activate the indication of maintenance required after a certain number of operations, preset by the installer.
To activate and select the number of operations, proceed as follows:
Press the <PG> button, OFF is displayed, indicating that the function is disabled (default).
Select one of the numbers shown (from OFF to 100) by using the <+> and <-> keys . The figures express the value of hundreds of
cycles (e.g.: the number 50 means 5000 operations).
Press OK to activate the function. The PROG message is displayed.
When the flashing light flashes for around 10 sec at end of operation, this means that maintenance operations are needed.
RESET of the control unit. WARNING: Returns the control unit to the default values.
When the <PG> push-button is pressed once, the RES wording begins to flash, if the push-button<PG> is pressed once more, the
control unit is reset.
Note: neither the transmitter codes nor the position and stroked of the gate leaf will be erased from the receiver.
RADIO (RAD)
NUMBER OF CYCLES (Nman)
MAINTENANCE (maci)
RESET (RES)
FUNCTION
(OFF)
(OFF)
(ON)
(OFF)
(OFF)
17

Publicité

Table des Matières
loading

Table des Matières