1) Cut off power supply.
2) Manually release the door/gate and push it for about half stoke. Lock the door again.
3) Restore power supply.
4) Check that OPEN/CLOSE pushbuttons are working in the wanted way, otherwise swap the motor/inverter wiring (U<>V)
The inverter allows to enhance the functional performance of the motor as regards control of the torque, speed and safety.
Although the pre-installed inverter is provided with programming functions, none of them must be changed by the installer
because the WAVE control unit directly controls all the operating parameters. If the device is to be replaced, ask an original spare
part to the manufacturer and carry out its wiring in compliance with connections shown in the handbook supplied with the spare part
itself. Do not use inverters which are not supplied by the manufacturer for any reason whatsoever.
The programming of the various functions of the control unit is carried out using the LCD display on the control unit and setting the
desired values in the programming menus described below.
The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer.
The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch.
Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the software
release.
1 – Press the button <PG>, the display goes to the first menu, Parameters "PAR".
2 – With the <+> or <-> button, select the menu you want.
3 – Press the button <PG>, the display shows the first function available on the menu.
4 – With the <+> or <-> button, select the function you want.
5 – Press the button <PG>, the display shows the value currently set for the function selected.
6 – With the <+> or <-> button, select the value you intend to assign to the function.
7 – Press the button <PG>, the display shows the signal "PRG" which indicates that programming has been completed.
Pressing <-> with the display turned off means an impulse of P.P.
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without making any
changes.
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 30s the control unit quits programming mode and switches off the display.
The tables below describe the individual functions available in the control unit.
MENU
Automatic closure time. It is activated only with "TCA" logics :ON
TCA
At the end of the preset time, the control unit starts a new closing operation.
The passage left open by the door/gate leaf during the partial opening controlled
Tped
by the pedestrian inoput, is adjusted.
The value is in seconds.
Motor operating time.
TM
The maximum duration of the opening and closing operation is adjusted.
The value is automatically set by the AUTOSET function.
The opening and closing speed is adjusted.
FSTS
"See section "How to adjust speed and braking".
Speed during braking is adjusted.
sldS
See section "How to adjust speed and braking".
PMO
The torque applied to motor 2 in the opening* phase is adjusted.
PMC
The torque applied to motor 2 in the closing* phase is adjusted.
The trigger time of the anti-crash device is adjusted during the normal speed
sEav
phase*.
0:Off-90: maximum sensibility - 1: minimum sensitivity
The trigger time of the anti-crash device is adjusted during the braking phase*.
sEar
0:Off-90: maximum sensibility - 1: minimum sensitivity
It is activated with AUX 1 parameter only, preset to value 2.
TLS
The activation time of the service light is adjusted.
HOW TO CHECK CONNECTIONS
INVERTER
PROGRAMMING
TO ACCESS PROGRAMMING
NOTES
PARAMETERS, LOGIC AND SPECIAL FUNCTIONS
PARAMETERS (PAR)
FUNCTION
MEMO
MIN-MAX-(Default)
1-240-(40s)
1-120-(3)
5-240-(240s)
20-90-(45)
5-40-(25)
1-99-(20%)
1-99-(20%)
1-90-(0%)
1-90-(0%)
1-240-(60s)