Technical Data; Wire Diagram - Beninca BRAINY 24 Mode D'emploi

Masquer les pouces Voir aussi pour BRAINY 24:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32

TEChNICAL DATA

Contol unit supply
Power supply
Output supply
Maximum motor current
Output supply accessories
Protection level
Operating temp.
Radio receiver
Rolling code transmitters supported
IMPORTANT: The control unit is equipped with the Autoset function to automatically set the main functioning values based on the
type of installation.
The AUTOSET function must be repeated at every function parameter change or upon change of automation conditions. See the
AUTO menu for further information.
Wire connections shown in Fig. 1 are described hereunder:
Terminal No.
Function
1-2
Motor 1
3-4
Motor 2
5-6
Flashing light
7-8
Lock
SCA/
9-10
PHOTO TEST
11-12
24 Vac/dc
13
COM/ENC+
14
SWO1/ENC1
15
SWC1
16
SWO2/ENC2
17
SWC2
18
PHOT
19
PHOT C
20
STOP
21
OPEN
22
CLOSE
23
PED
24 Vdc
230 Vac 50/60 Hz or 115Vac 50/60Hz according to the version
1/2 motor 24Vdc
5+5 A
24Vdc 500mA max.
IP55
-20°C / +50°C
built in 433,92 MHz confgurabile (rolling-code or programmable + rolling-code)
64
BRAINY 24 CONTROL UNIT
AUTOSET FUNCTION

WIRE DIAGRAM

Description
Connection, motor 1: 24VDC 5A max
Connection, motor 2: 24VDC 5A max
Connection, flashing light 24VDC 15W max.
Output, 12Vdc/10W power supply for electric lock (7:0V, 8:+12V)
Contact free from N.O. Voltage, may be configured as open gate indicator or photocell
test.
For use as "Open gate indicator" the TEST1 and TEST2 logics must be OFF
For use as photocell test it is sufficient to activate one or both TEST logics and connect
the photocells as indicated in Fig.3.
Output, accessory power supply, 24VAC/0.5A max.
IMPORTANT: If the battery charger board is installed, the output (without mains power
connected) has a 24Vdc polarised voltage.
Make sure the devices are correctly connected (i.e. 11:+24Vdc / 12:-0Vdc).
Common for limit switch and all the command inlets or encoder power supply.
Motor 1 OPEN limit switch input (N.C. contact) or Motor 1 Encoder connection.
Motor 1 CLOSE limit switch input, (N.C. Contact)
Motor 2 OPEN limit switch input, (N.C. Contact) or Motor 2 Encoder connection.
Motor 2 CLOSE limit switch input, (N.C. Contact)
Input, photocell activated in both opening and closing phases
Input, photocell activated in closing phase only (Normally closed contact)
Input, STOP push-button (Normally closed contact)
Input, OPEN push-button (Normally open contact).
It is possible to connect a timer for opening in time slots.
Input, CLOSE push-button (Normally open contact)
Pedestrian button input (N.O. Contact), controls the motor 1 opening, see TPED pa-
rameter.