Appliance Recess, With Ventilated Remote Motor - Vitrifrigo C25L Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

The recess must respect the minimum distances between the appliance and the
surrounding structure and it must have suitable ventilation openings communicating
directly with the open space in the room, in order to obtain correct air circulation by
means of the chimney effect, as indicated in annex 2 - figure 2
The recess must ensure that all possible live parts of the appliance are not directly
accessible as well as the ventilation openings, by fitting them with suitable grilles.
The grilles must have openings with max. dimension of 5 mm.
The envisioned ventilation openings are:
1.
with dimension no less than 120 mm in height for the dimension of the refrigeration
in width if positioned behind, which must always be associated to another opening
of at least 120x12 mm positioned on the side of the condenser (anx.2 - fig.2).
2.
of dimensions 120x120mm if positioned on both sides, as indicated in annex 2 - fig.2
La distanza minima tra le varie parti dell'apparecchio e la struttura di incasso non deve
essere inferiore a 75mm. (anx.2 - fig.2)
For recess situations in spaces where the minimum distance of 75mm is respected only
in the rear part of the appliance, make the ventilation openings on the same side
respecting the indications for the position, number and dimensions shown in fig.2.
For recess situations with surfaces in contact with the upper and lower parts of the
appliance, make the ventilation openings at the top and bottom of the appliance as
indicated in fig.2.
In all the situations of the described ventilation openings, only the minimum distance of
75mm from the sides of the appliance may not be observed.

Appliance recess, with ventilated remote motor.

The size of the front opening to be prepared for recessing the appliance must respect the
dimensions of the refrigerator (see annex 1).
The recess must respect the minimum distances between the remote motor and the
surrounding structure and it must have suitable ventilation openings communicating
directly with the open space in the room, in order to obtain correct air circulation by
means of the chimney effect, as indicated in annex 2 - figure 3
The recess must ensure that all possible live parts of the appliance are not directly
accessible as well as the ventilation openings, by fitting them with suitable grilles.
The grilles must have openings with max. dimension of 5 mm.
The ventilation openings must have dimensions no smaller than 120x120 mm and
positioned on both sides, as per figure 3.
24
ENG