G
Model:
ES 13 - ESP 13 - ESA 13 - ESR 13 - ESRC 13 - ESC 13
Heating input (min-max):
Nominal heat output:
Reduced heat output:
CO emissions at 13% O2 (nominal heat):
CO emissions at 13% O2 (reduced heat):
Efficiency at nominal heat output:
Efficiency at reduced heat output:
Flue gas temperature at nominal heat output:
Flue gas temperature at reduced heat output:
Draught (min-max):
Voltage:
Frequency:
Electrical comsumption (ignition):
Electrical comsumption (working):
Weight:
Exhaust gas flow (at rated power)
Exhaust gas flow (reduced power)
The indicative heatable surface is 240 m
Model:
ES 11 - ESP 11 - ESA 11 - ESR 11 - ESRC 11 - ESC 11
Heating input (min-max):
Nominal heat output:
Reduced heat output:
CO emissions at 13% O2 (nominal heat):
CO emissions at 13% O2 (reduced heat):
Efficiency at nominal heat output:
Efficiency at reduced heat output:
Flue gas temperature at nominal heat output:
Flue gas temperature at reduced heat output:
Draught (min-max):
Voltage:
Frequency:
Electrical comsumption (ignition):
Electrical comsumption (working):
Weight:
Exhaust gas flow (at rated power)
Exhaust gas flow (reduced power)
The indicative heatable surface is 200 m
WARNING!
In case of fire inside the chimney, immediately contact the firefighters.
2,09 kW - 10,0 kW
8,8 kW
2,0 kW
0,013 %
0,014 %
88,78%
95,48%
154,2 °C
52,3 °C
10-12 Pa
230 V
50 Hz
280 W
100 W
83 kg
7,8 g/S
2,7 g/S
3
2,08 kW - 8,5 kW
7,64 kW
2,0 kW
0,017 %
0,014 %
89,84 %
95,48 %
138,2 °C
52,3 °C
10-12 Pa
230 V
50 Hz
280 W
100 W
81 kg
6,9 g/S
2,7 g/S
3
24