ExtraStove ES 11 Manuel D'installation page 13

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

300230/ES/ESP/ESA/ESR/ESRC/ESC
Carefully read the precautions and follow the procedures correctly.
WARNING!
In case of breakage or poor functioning always contact the Authorized Assistance Cen-
tre; any attempt to remove parts or perform maintenance on the device can expose
the user to electrical shock danger.
The stove contains parts whose maintenance must be done by the Authorized Assi-
stance Centre.
The stove is a heating device; its parts reach extreme temperatures and contact wi-
thout adequate protection can provoke burns of various degrees.
Pay particular attention to children.
In case of a transfer, contact the Authorized Assistance Centre for the removal and
new installation.
Do not insert fingers or other objects in the air flow exit slits.
Inside the device there is a high speed fan that could cause grave personal injury.
Pay particular attention to children.
Do not remain for long periods directly exposed to the flow of hot air. Direct and pro-
longed exposition to the cold air could be hazardous to health.
Pay particular attention in rooms where there are children, the elderly or the ill. In case
the stove functions poorly, shut down the device immediately and contact the Autho-
rized Assistance Centre.
The continued use of the device in said conditions can cause fires or flashes.
Norms and conformity declarations
Legislation
• Our company declares that the stove conforms to the following norms for EC European
Directive marking.
• 2014/30/EU, ElectroMagnetic Compatibility Directive (EMCD)
• 2014/35/EU, Low Voltage Directive (LVD)
• 2011/65/EU, Restriction of the use of certain hazardous substances Directive (RoHS
Directive)
• Regulation of the CPR (EU 305/2011).
• For installation in Italy refer to the UNI 10683/98 or successive moditcations; the te-
chnician installing the hydrothermal sanitary system will issue the declaration of con-
formity according to L. 37/2008. The installation and the use of appliance has to be in
accordance with local and national laws and with European norms.
• EN 55014-1; EN 55014-2; EN 61000-3-2; EN 61000-3-3; EN 60335-1;
EN 60335-2-102; EN 62233; EN 14785.
Responsibility
The manufacturer declines every direct or indirect, civil or penal responsibility due to:
• Poor maintenance.
• Failure to observe the instructions contained in the manuals.
• Use in non-conformity with the safety directives.
• Installation in non-conformity with the norms in force in the country.
• Installation by unqualified or untrained personnel.
• Modifications and repairs not authorized by the manufacturer.
• Use of non-original replacement parts.
• Exceptional events.
• Use of pellets not approved by the manufacturer.
Installation
Flue
The flue must meet the following requirements:
• No other type of chimney, stove, boiler or hood vent must be connected (fig.1).
• It must be adequately distanced from combustible or inflammable material by means
of an air cavity or opportune insulation.
• The internal section must be uniform, preferably circular: the square or rectangular
sections must have rounded corners with a radius of no less than 20 mm, a maximum
relationship between the sides of 1.5; the walls as smooth as possible with no narro-
wed sections, regular curves and no discontinuities, with deviations from the axis not
more than 45°.
• Every device must have its own flue with a diameter equal to or larger than the stove's
smoke clearing tube and a height not less than that declared.
• Never use two stoves, a chimney and a stove, a stove and a wood kitchen, etc in the
same environment, since the draught of one could damage the draught of the other.
Installation manual
During the stove installation operation, keep children out of the work area to avoid
unforeseen accidents.
Do not block or cover in any way the body of the stove or obstruct the slits placed on
the upperside.
Obstructing said slits can cause fires.
Do not use the stove in areas containing precision devices or works of art.
The quality of the conserved objects may deteriorate.
Do not expose animals or plants to direct air flow from the unit.
Prolonged direct exposition to the flow of air from the stove can have negative effects
on plants and animals.
Occasionally ventilate the room during the use of the device.
Insufficient ventilation can be the origin of insufficient oxygen in the room.
Do not expose the stove to contact with water.
The electrical insulation could be damaged, with the consequent possibilities of elec-
trocution and breakage due to the thermal extremes.
Verify the installation conditions to locate eventual damage.
After the stove has completed 1000-1200 hours of operation (the lower screen will
read "SErV"), contact the Authorized Assistance Centre for cleaning and ordinary main-
tenance.
Do not use inflammable gas near the stove.
Unhook the automatic switch if the device will not be used for long periods of time.
We check the start up of all our stoves.
• Collective type ventilation ducts that can lower the atmospheric pressure in the in-
stallation environment are not permitted, even if installed in environments that are ad-
jacent to and communicating with the locale of the installation.
• It is forbidden to make fixed or mobile openings in the flue to connect devices different
from that for which it is originally intended.
• It is forbidden to pass other air feeding channels or tubes for electrical system usage
through the flue, even if oversized.
• It is advisable that the flue be furnished with a chamber which collects solid material
and eventual condensation situated below the vertical entrance to the flue so that it
is easily opened and inspected through the air-tight door.
NO
13
WARNING!
NO
YES
Fig.1: methods for installing the flue
G

Publicité

Table des Matières
loading

Table des Matières