TROUBLESHOOTING
F A U L T
Water drips out
when moving unit
Unit does not
operate
Unit operating,
but room not dry
Unit collects too
little water
If the problem you are experiencing is not listed here, call your local distributor or contact
our Service Department at 800-932-3030 for further assistance.
SPECIFICATIONS
Model
Weight
Dimensions
(H × D × W)
Volts
Frequency
Amps
Power
Water removal AHAM
(80°F/60% RH)
Water removal saturation
(90°F/90% RH)
Water removal low grain
(80°F/20% RH)
Operating range
Process air (max.)
Noise level (avg.)
Air filter
Drain hose
Power cord
Construction
Safety
Specifications are subject to change without notice. Some values
may be approximate.
*Fan speed varies automatically for optimized performance.
07-02300A F600 (115V)
C A U S E
Unit was unplugged before
purging was complete.
Unit not switched on.
No power to machine.
Not enough time to dry.
Poor air movement in room.
Excessive moist air infiltration.
Room air is dry.
Room temperature is too low.
Filter is full.
Coils are clogged.
LGR 6000Li (F600)
100 lbs. | 45 kg
32.1 × 19.8 × 20.0 in.
81.5 × 50.3 × 50.8 cm
115V
60Hz
6.6A
759W
100 pts. | 47.3 L / day
204 pts. | 96.5 L / day
11 pts. | 5.2 L / day
33°F–100°F | 1°C–38°C
330 CFM
60 dB
Part no. F579 (24 pack)
40 ft. | 12.2 m
25 ft. | 7.6 m
Rotomolded shell
ETL certified CSA 22.2 no. 92
S O L U T I O N
Purge unit before moving. See "At the End of the Job," p. 4.
Switch unit on.
Plug in unit; check power cord connection at wall outlet and at
base of unit.
Make sure "Humidistat" is OFF.
Allow more time for drying.
Increase air movement with air movers.
Seal off area to reduce infiltration.
Make sure "Humidistat" is OFF.
Confirm humidity level with hygrometer.
Increase room temperature.
Check filter. Replace as necessary.
Check coils. Clean as necessary.
Warranty information is available at www.dri-eaz.com.
Be sure to visit warranty.drieaz.com and register your
purchase. Your registration will help us provide you with
updated product information as needed.
For proper disposal, this unit should be taken to a
recycler licensed to process refrigeration equipment.
9