TEMPERATURE DISPLAY, TEMPERATURE CONTROL FOR CHARGE PUMP
In the case that external controls are installed, it must be ensured that the boiler temperature cannot exceed
95°C during practical operation.

FIRST COMMISSIONING

The room where the device is used must be frost-free.
Initial commissioning and heating must be monitored by a specialist.
Before initial commissioning, the buffer tank must be filled with prepared heating water and bled.
After heating, the set temperature and the actual temperature should be checked to ensure that they corres-
pond.
The volume of the water contained in the tank changes, if it is heated.
The expansion water created in the internal boiler during the heating process must be absorbed up by an appro-
priate expansion vessel. Please take the size of the expansion vessel from the Manufacturer's documentation.
On buffer tanks with electrical components, all nationally and internationally valid standards and regulations
must be observed and put into practice. All work may only be performed by a licensed professional.
The independent switching off of any possible electric heating element mounted resp. of the boiler by the sys-
tem must be checked.
This tank can be used by children eight years old and older as well as by persons with reduced physical, sensory
or mental capabilities or who lack experience and knowledge if they are supervised or if they have been trained
with regard to the safe use of the tank and understand the resulting risks. Children may not play with the tank or
its packaging. Cleaning and user maintenance may not be performed by children without supervision.
DECOMMISSIONING, EMPTYING
If the storage tank is taken out of operation or not used for a longer period, then it must be disconnected all-pole
from the electric power grid in the case of electric heating. Turn off the lead switch or the automatic cutout.
In frost-prone rooms, the buffer tank must be drained before the start of the winter period or it must be prepared
accordingly with anti-freeze.
Caution: hot water may exit during emptying!
In addition, where there is a risk of frost, it is important to note that not only the water in the buffer tank and
warm water pipes can freeze, rather that all the pipes to the heating body and to the device can freeze too. It is
therefore advisable to drain all water-bearing fittings and pipes in the heating circuit.