Complete Reset Of The Memory; How To Replace A Faulty Device - Urmet 1103 Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

and the '0' digit increases by one unit,
approximately once a second, cyclically (i.e.
moving from 9 to 0).
Release the key when the digit you want to set is
displayed.
Press and release the rear red key again twice
so as to set the other two digits. At this point, the
following will appear on the display:
where 'JKL' is the password set. Press the
rear red key briefly to confirm the password.
In this way, you will access the MASTER key
programming menu from which you can exit using
a MASTER key as described in the 'Installation
and Configuration' paragraph.

COMPLETE RESET OF THE MEMORY

The entire contents of the memory can be deleted, for
example to re-use the device in a new installation.
In the case of a complete memory reset, the
password and all the user keys held in the memory
are deleted.
Proceed as follows:
− switch off the device.
− press the rear red button and, holding it down,
switch on the device again.
− hold the button down until the following caption is
cleared:
At this point, the display will start a count-down,
clearing the user key memory.
− release the button.
− wait for the end of the count and return to normal
functioning.

HOw TO REPLACE A FAULTY DEVICE

To replace a faulty device, the key memory must be
moved from one module to another to avoid having
to reprogram the user keys.
Proceed as follows:
− switch off the faulty module.
− open the rear cover and carefully extract the
memory device exerting leverage on both sides
with a small screwdriver.
− insert the memory device in the new module,
powered off, paying particular attention to the
direction of insertion as shown in the figure.
1
'JKL'
HOw TO STORE MORE THAN 500
USER KEYS
In particular applications, it may be necessary to
store more than 500 user keys.
In this case, use the 110/51 (1000 keys) or 110/5
(000 keys) memory.
Replace the standard key memory with the new
memory, proceeding as follows:
− switch off the door opener module;
− open the rear cover and carefully extract the
standard memory device, exerting leverage on
both sides with a small screwdriver;
− insert the new memory device, paying particular
attention to the direction of insertion, as shown in
the figure;
− switch on the module again.
At power-up, the door release module automatically
recognizes the higher capacity memory without
requiring any further operations.
NOTE: in this case, the decimal points are used
to distinguish the keys with number above
999; the right-hand decimal point will
indicate keys between 1000 and 1999;
the central decimal point will indicate keys
between 2000 and 2999.
DS1103-006B

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1103/2

Table des Matières