Store User Key; User Key Deletion/Replacement; Setting Of Release Open Time - Urmet 1103 Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

In any case, if no operation is performed for 3
minutes after accessing programming, the device
automatically returns to normal functioning.
When returning to normal functioning from the
programming phase, the following caption may
appear on the display for few seconds
(abbreviation of 'Store') this can be considered
normal and indicates that the device is permanently
storing the information received. Wait for few
seconds: the caption will disappear and the device
will return to normal functioning.
The individual sub-menus are illustrated below.

STORE USER KEY

Move the key to be stored towards the front panel.
The buzzer will emit a continuous beep and the
display will show the 'number of the key' (i.e. the
position of the key in the memory). To facilitate
management, it is advisable to apply an adhesive
label to the key and to write the 'key number' on
this.
To check that the key has been effectively stored,
move the key towards the front panel: the buzzer
will emit 3 beeps (instead of one) and the display
will show the 'number of the key'.
Repeat as explained above for all user keys to be
stored.
To return to normal functioning, rest a MASTER key
on the front panel.

USER KEY DELETION/REPLACEMENT

To delete a user key that has been lost, you MUST
know the 'number of the key' lost.
Present the MASTER key and hold it in place for
at least  seconds. The following will appear on the
display:
and the '0' digit will increase by one unit once a
second, cyclically (i.e. passing from 9 to 0).
10
Remove the MASTER key when the digit you want
to set is displayed (the first digit of the number of
the lost key).
Repeat the above operations with the MASTER key
twice so as to set the other two digits. At this point,
the display will show:
where 'NMK' is the number of the lost key that is to
be deleted or replaced.
− If the number entered 'NMK' is not correct (i.e.
it does not correspond to the number of the key
to be deleted), do not perform other operations:
after 7 seconds, the device will return to normal
functioning WITHOUT deleting anything.
− If the number set 'NMK' is correct, approach
(within 7 seconds) the MASTER key: the buzzer
will emit a beep and the key will be deleted from
the memory. The flashing key symbol will be
shown on the display for 7 seconds:
If you want to store a new key and to assign the
SAME 'key number' to this as that you have just
canceled, move the new key towards the front panel.
At this point (or after 7 seconds), the device will
redisplay the key delete/replace invitation symbol:
Repeat the same operations for all the keys to be
deleted or replaced.
To return to normal functioning, place a MASTER
key close to the front panel.

SETTING OF RELEASE OPEN TIME

When you access this menu, the display indicates
the currently set door release time (factory setting:
't00').
The door release time can be set between 0 and 99
seconds.
Move the MASTER key close to the panel and hold
it in position for at least  seconds. The following will
appear on the display:
'NMK'
DS1103-006B

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1103/2

Table des Matières