Advanced Programming Functions; Deletion Of Available Keys; Access Password; Access In The Case Of Loss Of Master Key/Storage Of New Master Keys - Urmet 1103 Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

and the '0' digit will increase by one unit,
approximately once a second, cyclically (i.e. moving
from 9 to 0).
Remove the MASTER key when the digit to be set
is displayed.
Approach and remove the MASTER key so as to
also set the second digit. At this point, the display
will show:
where 'XY' is the new door release time set.
After 3 seconds, the display will return to normal
functioning.
ADVANCED PROGRAMMING
FUNCTIONS
A number of particular functions, not generally used,
are described below.

DELETION OF AVAILABLE KEYS

To delete an available user key from the memory,
you can use a simpler procedure than that described
above for lost keys:
− using a MASTER key, access the deletion menu
with the following shown on the display:
− present the key to be deleted.
− if the key presented is effectively present in the
memory, the buzzer will emit three beeps and the
display will show the 'key number' for approx. 7
seconds.
− when the key number is shown on the display,
present the MASTER key to confirm deletion.
To restore normal functioning, present a MASTER
key to the front panel.
ACCESS IN THE CASE OF LOSS OF
MASTER KEY/STORAGE OF NEw
MASTER KEYS
It is always possible to access a device, even
without the MASTER keys, provided you have a
blank key, i.e. a key that has never been stored as
user key on that device.
Proceed as follows:
− open the Sinthesi frame, so as to access the rear
red button.
DS1103-006B
'tXY'
− press the rear red button briefly;
− wait until the following is displayed:
− press the rear red button again briefly;
− present the blank key which will be stored as
MASTER key in addition to or in replacement of
(if 3 have already been stored) of the MASTER
keys present.
− present this new MASTER key for at least 7
seconds so as to restore normal functioning.
− use this new MASTER key to access the device.

ACCESS PASSwORD

Access from the rear red button can be protected
using a 3-digit password.
When a password is entered in the device, the
rear red button can be accessed subsequently only
re-entering the password.
WARNING:
If all the MASTER keys of a device equipped
with password are lost and you have forgotten
the password, IT IS IMPOSSIBLE TO ACCESS
DEVICE PROGRAMMING. In this case, get in
touch with the Urmet technical assistance service
directly which will eliminate the password without
deleting any of the user keys.
The password can be set on any device without
password (therefore on any device that leaves the
factory).
Once the password has been entered, it cannot be
modified.
It can be deleted only using the complete memory
reset procedure (see below): IT IS ADVISABLE
THEREFORE TO ENTER THE PASSWORD
BEFORE STARTING TO STORE THE USER KEYS
SO THAT THIS CAN BE DELETED IN THE CASE
OF ERRORS DURING THE ENTRY PHASE.
Proceed as follows:
− press the rear red key briefly;
− wait until the following is displayed:
− press the rear red key and hold it down. The
following is displayed:
11