Clearance to combustible walls
To find out whether the wall by which the stove is to be placed is combustible or not,
please contact your architect or the local building authorities.
If the floor is combustible, the stove must be placed on a non-combustible plate such
as steel, glass or stone. See pages 9 and 16 for additional information concerning floor
protection.
It may be possible to reduce clearances to combustible walls using the methods
detailed in NFPA 211. Seek guidance and permission in your locality as permits or
inspections may be required.
Clearances may only be reduced by means approved by regulatory authority
Minimum Rear vent Clearance
(*
838040590 High socket complete
Model: Q-Tee II C USA
Solid Fuel Room Heater
d Fuel Room Heater
A: Side Wall to Unit
B: Back Wall to Unit
C: Corner Wall to Unit 13.5"/343mm
D: Ceiling Height
E: Front Wall / Furnishing 36"/915mm
F: Back Wall to Pipe
arances to combustible surfaces
G: Side Wall to Pipe
H Corner Wall to Pipe 22.5"/572mm
Parallel to Wall.
Parallel to Wall.
Back wall
Back wall
A
G
RAIS A/S
RAIS A/S
Industrivej 20, DK-9900 Frederikshavn, Denmark
Industrivej 20, DK-9900 Frederikshavn, Denmark
With Pedestal With Pedestal* No Pedestal
14"/356mm
12"/ 305mm
Date of manufacture
Date of fabrication
45"/1143mm
17"/432mm
24"/610mm
A
G
User Manual Q-Tee II USA / Q-Tee II C USA
)
Rear vent
14"/356mm
12"/305mm
Date of manufacture
N/A
Date of fabrication
45"/1143mm
36"/915mm
N/A
24"/610mm
N/A
45° to Wall
Adjacent wall
For Use With Solid Woo
For Use With Solid Wood Fu
15"/381mm
15"/381mm
Month
Month
15.5"/394mm
Mois
Mois
45"/1143mm
36"/915mm
20"/508mm
25"/635mm
24.5"/622mm
45° to Wall
Adjacent wall
C
C
H
H
19