Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

EDKZNXXXX−001
.G&!
Global Drive
EZN
150 ... 230 A
EZN3x0022H150, EZN3x0017H200, EZN3x0015H230
Unterbau−Netzfilter
Footprint mains filter
Filtre réseau en montage arrière
Montageanleitung
Mounting Instructions
Instructions de montage
l

Publicité

Table des Matières
loading

Sommaire des Matières pour Lenze Global Drive EZN3-0022H150 Serie

  • Page 1 EDKZNXXXX−001 Global Drive .G&! Montageanleitung Mounting Instructions Instructions de montage 150 ... 230 A EZN3x0022H150, EZN3x0017H200, EZN3x0015H230 Unterbau−Netzfilter Footprint mains filter Filtre réseau en montage arrière...
  • Page 3 Lesen Sie zuerst diese Anleitung und die Dokumentation zum Grundgerät, bevor Sie mit den Arbeiten beginnen! Beachten Sie die enthaltenen Sicherheitshinweise. Please read these instructions and the documentation of the standard device before you start working! Observe the safety instructions given therein! Lire le présent fascicule et la documentation relative à...
  • Page 4 EZN−021 0Abb. 0Tab. 0 EDKZNXXXX−001 DE/EN/FR 3.0...
  • Page 5: Lieferumfang

    Lieferumfang Anzahl Beschreibung Filter Montageanleitung Beipack mit ... 4 x Befestigungswinkel 12 x Schrauben M8 x 16 mm 12 x Federringe A8 1 x Schirmblech für Thermokontakt−Leitung 2 x Schrauben M4 x 8 mm 2 x Ringschrauben M8 für Transport Elemente am Filter Position Beschreibung...
  • Page 6: Informationen Zur Gültigkeit

    Informationen zur Gültigkeit Diese Anleitung ist gültig für ƒ Unterbau−Netzfilter EZN3x0022H150 ƒ Unterbau−Netzfilter EZN3x0017H200 ƒ Unterbau−Netzfilter EZN3x0015H230 Identifikation Hans-Lenze-Straße 1 D-31855 Aerzen Made in Germany  Type: 8200vec080 Abb. 0−1 Typenschild  Typenschlüssel xxxx xxxx Produktreihe Zubehör Filtertyp N = Netzfilter...
  • Page 7 Bei Betrieb mit erhöhter Bemessungsleistung Dokumenthistorie Materialnummer Version Beschreibung .G&! 05/2011 TD29 Neuauflage wegen Neuorganisation des Unternehmens 13216422 10/2007 TD29 Überarbeitung 461664 01/2003 Erstausgabe Tipp! Informationen und Hilfsmittel rund um die Lenze−Produkte finden Sie im Download−Bereich unter http://www.Lenze.com EDKZNXXXX−001 DE/EN/FR 3.0...
  • Page 8: Table Des Matières

    Inhalt Sicherheitshinweise ............Verwendete Hinweise .
  • Page 9: Sicherheitshinweise

    Sicherheitshinweise Verwendete Hinweise Sicherheitshinweise Verwendete Hinweise Um auf Gefahren und wichtige Informationen hinzuweisen, werden in dieser Dokumenta- tion folgende Piktogramme und Signalwörter verwendet: Sicherheitshinweise Aufbau der Sicherheitshinweise: Gefahr! (kennzeichnet die Art und die Schwere der Gefahr) Hinweistext (beschreibt die Gefahr und gibt Hinweise, wie sie vermieden werden kann) Piktogramm und Signalwort Bedeutung Gefahr von Personenschäden durch gefährliche elektrische...
  • Page 10: Restgefahren

    Sicherheitshinweise Restgefahren Restgefahren Gefahr! Gefährliche elektrische Spannung Alle Leistungsanschlüsse führen bis zu 3 Minuten nach Netz−Ausschalten gefährliche elektrische Spannung. Mögliche Folgen: Tod oder schwere Verletzungen beim Berühren der Leistungsanschlüsse. ƒ Schutzmaßnahmen: Vor Arbeiten an den Leistungsanschlüssen Netz abschalten und mindestens ƒ...
  • Page 11 Sicherheitshinweise Restgefahren Stop! Hohes Gerätegewicht Das Gerät ist sehr schwer und muss für die Montage angehoben werden. Mögliche Folgen: Personenschäden, insbesondere Rückenschäden beim Anheben bzw. Halten ƒ des Gerätes Sach− und Personenschäden durch Herunterfallen des Gerätes ƒ Schutzmaßnahmen: Gerät nur mit einer für das Gerätegewicht zugelassenen ƒ...
  • Page 12: Technische Daten

    Technische Daten Allgemeine Daten und Einsatzbedingungen Technische Daten Allgemeine Daten und Einsatzbedingungen Angaben zu Netzen Netzformen Mit geerdetem Y−Punkt (TT−/TN−Netze) Betrieb uneingeschränkt erlaubt Andere Netzformen Anweisungen über besondere Maßnahmen in der Dokumen- tation zum Grundgerät beachten! Schutz Schutzart EN 60529 IP 20 nicht im Anschlussbereich der Klemmen...
  • Page 13: Bemessungsdaten

    Technische Daten Bemessungsdaten Bemessungsdaten Grundlage der Daten Netz Spannung Spannungsbereich Frequenzbereich f [Hz] 3/PE AC 320 − 0 % ... 440 + 0 % 45 − 0 % ... 65 + 0 % 3/PE AC 432 − 0 % ... 528 + 0 % 45 −...
  • Page 14: Mechanische Daten

    Technische Daten Mechanische Daten Mechanische Daten EZN−022 Alle Maße in Millimeter. Masse [kg] EZN3A0022H150 62.5 EZN3B0022H150 77.0 EZN3A0017H200 93.0 EZN3B0017H200 97.0 EZN3A0015H230 EZN3B0015H230 EDKZNXXXX−001 DE/EN/FR 3.0...
  • Page 15: Mechanische Installation

    Mechanische Installation Wichtige Hinweise Mechanische Installation Wichtige Hinweise Der Montageort muss den in den Technischen Daten genannten ƒ Einsatzbedingungen immer entsprechen (¶ 12). Ggf. zusätzliche Maßnahmen ergreifen. Die Montageplatte des Schaltschranks muss folgende Eigenschaften aufweisen: ƒ – elektrisch leitfähig – lackfrei Eine ungehinderte Luftzirkulation zum Abführen der Wärme muss gewährleistet ƒ...
  • Page 16: Bohrplan

    Mechanische Installation Bohrplan Bohrplan Standard−Montage > 100 > 100 EZN−025 EDKZNXXXX−001 DE/EN/FR 3.0...
  • Page 17 Mechanische Installation Bohrplan Montage−Variante > 100 100 ... 180 16.5 EZN−024 EDKZNXXXX−001 DE/EN/FR 3.0...
  • Page 18: Montageschritte

    Mechanische Installation Montageschritte Montageschritte Standard−Montage EZN−026 So montieren Sie das Filter: 1. Lesen Sie in der Dokumentation des Grundgerätes das Kapitel "Mechanische Installation". Informieren Sie sich insbesondere über ... – Vorsichtsmaßnahmen während der Montage – Anschlagstellen der Transport−Ringösen am Grundgerät 2.
  • Page 19 Mechanische Installation Montageschritte Montage−Variante EZN−023 So montieren Sie das Filter: 1. Lesen Sie in der Dokumentation des Grundgerätes das Kapitel "Mechanische Installation". Informieren Sie sich insbesondere über ... – Vorsichtsmaßnahmen während der Montage – Bohrabstände und Einbaufreiräume – Anschlagstellen der Transport−Ringösen am Grundgerät 2.
  • Page 20: Elektrische Installation

    Elektrische Installation Wichtige Hinweise Elektrische Installation Wichtige Hinweise Die Installation muss ƒ – den in den Technischen Daten genannten Einsatzbedingungen immer entsprechen (¶ 12). – nach EN 60204−1 ausgeführt werden. Bei der Auswahl des Leitungstyps beachten: ƒ – Die verwendeten Leitungen müssen den geforderten Approbationen am Einsatzort entsprechen (z.
  • Page 21: Anschlussdaten

    Elektrische Installation Anschlussdaten Anschlussdaten Anschlussleitungen "Line" EZN3x0022H150 4 x 70 4 x 2/0 AWG EZN3x0017H200 4 x 120 EZN3x0015H230 4 x 250 kcmil PE−Gewindebolzen [mm] [Nm] [lb−in] EZN3x0022H150 EZN3x0017H200 M10 x 40 SW 17 203.6 EZN3x0015H230 Klemmen "Thermokontakt" [Nm] [AWG] [mm] [lb−in] 0.6 ...
  • Page 22: Montageschritte

    Elektrische Installation Montageschritte Montageschritte EZN−027 So verdrahten Sie das Filter: 1. Schaltschrank spannungsfrei schalten und gegen wiedereinschalten sichern. 2. Anschlussleitungen "Load" 2 am Grundgerät anschließen. – Dokumentation des Grundgerätes beachten! 3. PE−Leiter mit Ringkabelschuh an PE−Gewindebolzen 1 montieren. – Anzugsmoment beachten! 4.
  • Page 23 Elektrische Installation Montageschritte EDKZNXXXX−001 DE/EN/FR 3.0...
  • Page 24 EZN−021 0Fig. 0Tab. 0 EDKZNXXXX−001 DE/EN/FR 3.0...
  • Page 25: Scope Of Supply

    Scope of supply Quantity Description Filter Mounting Instructions Accessory pack including ... 4 fixing brackets 12 screws M8 x 16 mm 12 spring washers A8 1 shield sheet for thermal contact cable 2 screws M4 x 8 mm 2 eye bolts M8 for the transport Elements on the filter Position Description...
  • Page 26: Validity Information

    Validity information These instructions are valid for ƒ Footprint mains filter EZN3x0022H150 ƒ Footprint mains filter EZN3x0017H200 ƒ Footprint mains filter EZN3x0015H230 Identification Hans-Lenze-Straße 1 D-31855 Aerzen Made in Germany  Type: 8200vec080 Fig. 0−1 Nameplate  Type code xxxx...
  • Page 27: Range Of Application

    .G&! 05/2011 TD29 New edition due to reorganisation of the company 13216422 10/2007 TD29 Revision 461664 01/2003 First edition Tip! Information and auxiliary devices around the Lenze products can be found in the download area at http://www.Lenze.com EDKZNXXXX−001 DE/EN/FR 3.0...
  • Page 28 Contents Safety instructions ............Notes used .
  • Page 29: Safety Instructions

    Safety instructions Notes used Safety instructions Notes used The following pictographs and signal words are used in this documentation to indicate dangers and important information: Safety instructions Structure of safety instructions: Danger! (characterises the type and severity of danger) Note (describes the danger and gives information about how to prevent dangerous situations) Pictograph and signal word...
  • Page 30: Residual Hazards

    Safety instructions Residual hazards Residual hazards Danger! Dangerous electrical voltage All power terminals remain live for up to three minutes after mains disconnection. Possible consequences: Death or severe injuries when touching the power terminals. ƒ Protective measures: Switch off the power supply and wait for at least three minutes before ƒ...
  • Page 31 Safety instructions Residual hazards Stop! Heavy device weight The device is very heavy and must be lifted for the mounting. Possible consequences: Injury to persons, particularly backache when lifting and holding the device, ƒ respectively Injury to persons and damage to material assets due to the device falling ƒ...
  • Page 32: Technical Data

    Technical data General data and operating conditions Technical data General data and operating conditions Mains data Mains types With grounded neutral (TT/TN systems) Operation permitted without restrictions Other mains types Observe instructions for special measures in the documentation for the basic device! Protection Degree of protection EN 60529...
  • Page 33: Rated Data

    Technical data Rated data Rated data Basis of the data Mains Voltage Voltage range Frequency range f [Hz] Lrated Lrated 3/PE AC 320 − 0 % ... 440 + 0 % 45 − 0 % ... 65 + 0 % 3/PE AC 432 −...
  • Page 34: Mechanical Data

    Technical data Mechanical data Mechanical data EZN−022 All dimensions in millimetres. Type Mass [kg] EZN3A0022H150 62.5 EZN3B0022H150 77.0 EZN3A0017H200 93.0 EZN3B0017H200 97.0 EZN3A0015H230 EZN3B0015H230 EDKZNXXXX−001 DE/EN/FR 3.0...
  • Page 35: Mechanical Installation

    Mechanical installation Important notes Mechanical installation Important notes The mounting location must always comply with the operating conditions specified ƒ in the technical data (¶ 32). Take additional measures if necessary. The mounting plate of the control cabinet must have the following properties: ƒ...
  • Page 36: Drilling Pattern

    Mechanical installation Drilling pattern Drilling pattern Standard mounting > 100 > 100 EZN−025 EDKZNXXXX−001 DE/EN/FR 3.0...
  • Page 37 Mechanical installation Drilling pattern Mounting variant > 100 100 ... 180 16.5 EZN−024 EDKZNXXXX−001 DE/EN/FR 3.0...
  • Page 38: Mounting Steps

    Mechanical installation Mounting steps Mounting steps Standard mounting EZN−026 How to mount the filter: 1. Read the chapter "Mechanical installation" in the documentation of the basic device. Read up particularly on ... – Precautionary measures while mounting – Hitching points of transport eye bolts on the standard device 2.
  • Page 39: Mounting Variant

    Mechanical installation Mounting steps Mounting variant EZN−023 How to mount the filter: 1. Read the chapter "Mechanical installation" in the documentation of the basic device. Read up particularly on ... – Precautionary measures while mounting – Bore spacings and free spaces –...
  • Page 40: Electrical Installation

    Electrical installation Important notes Electrical installation Important notes Installation must ƒ – always be in accordance with the operating conditions specified in the Technical data (¶ 32). – be carried out to EN 60204−1. Please observe the following when selecting the cable type: ƒ...
  • Page 41: Connection Data

    Electrical installation Connection data Connection data Connecting cables "Line" EZN3x0022H150 4 x 70 4 x 2/0 AWG EZN3x0017H200 4 x 120 EZN3x0015H230 4 x 250 kcmil PE stud [mm] [Nm] [lb−in] EZN3x0022H150 EZN3x0017H200 M10 x 40 SW 17 203.6 EZN3x0015H230 Terminals "thermal contact"...
  • Page 42: Mounting Steps

    Electrical installation Mounting steps Mounting steps EZN−027 How to wire the filter: 1. Deenergise the control cabinet and fuse it against re−energisation. 2. Connect the connection cables "Load" 2 to the basic device. – Observe the documentation for the basic device! 3.
  • Page 43 Electrical installation Mounting steps EDKZNXXXX−001 DE/EN/FR 3.0...
  • Page 44 EZN−021 0Fig. 0Tab. 0 EDKZNXXXX−001 DE/EN/FR 3.0...
  • Page 45: Equipement Livré

    Equipement livré Nombre Description Filtre Instructions de montage Kit de montage comprenant... 4 x équerres de fixation 12 x vis M8 x 16 mm 12 x rondelles élastiques A8 1 x tôle de blindage pour le câble du contact thermique 2 x vis M4 x 8 mm 2 x boulons à...
  • Page 46 Le présent document s’applique au produit suivant : ƒ Filtre réseau en montage arrière EZN3x0022H150 ƒ Filtre réseau en montage arrière EZN3x0017H200 ƒ Filtre réseau en montage arrière EZN3x0015H230 Identification Hans-Lenze-Straße 1 D-31855 Aerzen Made in Germany  Type: 8200vec080 Fig.0−1...
  • Page 47: Domaine D'utilisation

    Nouvelle édition en raison de la nouvelle organisation de l’entreprise 13216422 10/2007 TD29 Révision 461664 01/2003 Première édition Conseil ! Toutes les informations relatives aux produits Lenze peuvent être téléchargées sur notre site à l’adresse suivante : http://www.Lenze.com EDKZNXXXX−001 DE/EN/FR 3.0...
  • Page 48 Sommaire Consignes de sécurité ............Consignes utilisées .
  • Page 49: Consignes De Sécurité

    Consignes de sécurité Consignes utilisées Consignes de sécurité Consignes utilisées Pour indiquer des risques et des informations importantes, la présente documentation utilise les mots et symboles suivants : Consignes de sécurité Présentation des consignes de sécurité Danger ! (Le pictogramme indique le type de risque.) Explication (L’explication décrit le risque et les moyens de l’éviter.) Pictogramme et mot associé...
  • Page 50: Dangers Résiduels

    Consignes de sécurité Dangers résiduels Dangers résiduels Danger ! Tension électrique dangereuse Les raccordements de puissance sont encore sous tension jusqu’à 3 minutes après la coupure réseau. Risques encourus Mort ou blessures graves en cas de contact accidentel avec les ƒ...
  • Page 51 Consignes de sécurité Dangers résiduels Stop ! Appareil lourd Cet appareil est très lourd et doit être soulevé pour le montage. Risques encourus : Blessures, notamment lombalgies causées par le fait de soulever ou de ƒ maintenir l’appareil Blessures et dommages matériels causés par une chute de l’appareil ƒ...
  • Page 52: Spécifications Techniques

    Spécifications techniques Caractéristiques générales et conditions d’utilisation Spécifications techniques Caractéristiques générales et conditions d’utilisation Informations sur les réseaux Configurations réseau Avec point Y à la terre (réseaux TT/TN) Utilisation sans restriction Autres configurations réseau Respecter les indications concernant les mesures particulières dans la documentation de l’appareil de base ! Protection Indice de protection...
  • Page 53: Caractéristiques Assignées

    Spécifications techniques Caractéristiques assignées Caractéristiques assignées Données de base Réseau Tension Plage de tension Plage de fréquence f [Hz] 3/PE CA 320 − 0 % ... 440 + 0 % 45 − 0 % ... 65 + 0 % 3/PE CA 432 −...
  • Page 54: Caractéristiques Mécaniques

    Spécifications techniques Caractéristiques mécaniques Caractéristiques mécaniques EZN−022 Cotes en [mm] Type Poids [kg] EZN3A0022H150 62.5 EZN3B0022H150 77.0 EZN3A0017H200 93.0 EZN3B0017H200 97.0 EZN3A0015H230 EZN3B0015H230 EDKZNXXXX−001 DE/EN/FR 3.0...
  • Page 55: Installation Mécanique

    Installation mécanique Remarques importantes Installation mécanique Remarques importantes L’emplacement de montage doit impérativement remplir les conditions d’utilisation ƒ décrites dans les spécifications techniques.(¶ 52). Si nécessaire, prendre des mesures complémentaires. La plaque de montage de l’armoire électrique doit présenter les caractéristiques ƒ...
  • Page 56: Modèle De Perçage

    Installation mécanique Modèle de perçage Modèle de perçage Montage standard > 100 > 100 EZN−025 EDKZNXXXX−001 DE/EN/FR 3.0...
  • Page 57 Installation mécanique Modèle de perçage Variante de montage > 100 100 ... 180 16.5 EZN−024 EDKZNXXXX−001 DE/EN/FR 3.0...
  • Page 58: Opérations De Montage

    Installation mécanique Opérations de montage Opérations de montage Montage standard EZN−026 Pour monter le filtre : 1. Dans la documentation de l’appareil de base, lire le chapitre "Installation mécanique". Accorder une attention particulière aux points suivants : – Mesures de précaution à prendre pour le montage –...
  • Page 59 Installation mécanique Opérations de montage Variante de montage EZN−023 Pour monter le filtre : 1. Dans la documentation de l’appareil de base, lire le chapitre "Installation mécanique". Accorder une attention particulière aux points suivants : – Mesures de précaution à prendre pour le montage –...
  • Page 60: Installation Électrique

    Installation électrique Remarques importantes Installation électrique Remarques importantes L’installation doit ƒ – toujours respecter les conditions d’utilisation indiquées dans les spécifications techniques (¶ 52) ; – répondre aux exigences de la norme EN 60204−1. Lors du choix du type de câble, tenir compte des points suivants : ƒ...
  • Page 61: Données De Raccordement

    Installation électrique Données de raccordement Données de raccordement Câbles de raccordement "Line" EZN3x0022H150 4 x 70 4 x 2/0 AWG EZN3x0017H200 4 x 120 EZN3x0015H230 4 x 250 kcmil Boulon fileté PE [mm] [Nm] [lb−in] EZN3x0022H150 EZN3x0017H200 M10 x 40 SW 17 203.6 EZN3x0015H230...
  • Page 62: Opérations De Montage

    Installation électrique Opérations de montage Opérations de montage EZN−027 Pour raccorder le filtre : 1. Couper la tension dans l’armoire électrique et s’assurer que toute mise sous tension est exclue. 2. Raccorder les câbles "Load" 2 à l’appareil de base. –...
  • Page 63 Installation électrique Opérations de montage EDKZNXXXX−001 DE/EN/FR 3.0...
  • Page 64 © 05/2011 Lenze Automation GmbH Service Lenze Service GmbH Grünstraße 36 Breslauer Straße 3 D−40667 Meerbusch D−32699 Extertal Germany Germany +49 (0)21 32 / 99 04−0 00 80 00 / 24 4 68 77 (24 h helpline) Ê Ê +49 (0)21 32 / 7 21 90 +49 (0)51 54 / 82−11 12...

Table des Matières