V2 ALFARISS Mode D'emploi page 47

Masquer les pouces Voir aussi pour ALFARISS:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

DISPLAY
DATA
SP.AP
PAUS
ChiU
no
Ch.AU
no
0.5" - 20.0'
Ch.t r
no
0.5" - 20.0'
PA.t r
no - Si
LUCi
t .LUC
no
CiCL
AUS
Mon
t iM
biSt
FUNCTION
Pedestrian Start during the partial opening phase
This menu allows fixing the control unit conduct in case it receives a
Pedestrian Start command during the partial opening phase.
WARNING: a Start command in any phase of partial opening
will cause the total opening; the Start Pedestrian command is
always ignored during a total opening
The gate stops and goes to pause
The gate immediately starts closing
The gate goes on with the opening phase (command is ignored)
Automatic closing
In automatic mode, the control unit automatically recloses the gate on
expiry of the time limit set in this menu
Function deactivated
The gate recloses after the set time
(adjustable time from 0,5" to 20.0')
Closure after passage
During the automatic operation, the pause count down starts from the
set up value each time a photocell operates during the pause.
If the photocell operates during the opening time, this time will be
immediately stored as pause time.
This function allows having a fast closing as soon as transit through the
gate is completed, therefore, a time shorter than
used
Function deactivated
The gate recloses after the set time
(adjustable time from 0,5" to 20.0')
Pause after transit
In order to let the gate open for the shortest possible time, it is possible
to stop the gate once the passage before the photocells is detected.
If the automatic working is enabled, the time of the pause is
Courtesy lights
This menu allows setting the automatic operating of the courtesy lights
during the opening cycle of the gate
Timed function (from 0 to 20')
Function deactivated
On for the entire duration of the cycle
Auxiliary channel
This menu allows setting the operating of the relay of the lighting of the
courtesy lights by means of a remote control stored on the channel 4 of
the receiver
Timed function (from 0 to 20')
Bistable operation
Monostable operation
Ch.AU
is generally
45
DEFAULT MEMO
PAUS
no
no
no
Ch.tr
t .LUC
1 '00
Mon

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières