5. Turn off
5.1. General
Put the operating switch to 0: OFF when you finish the spraying activities.
5.2. Chemicals tank
Rinse everything with clean water, to remove chemicals out off the hoses, lance and spray gun.
Pull the suction hose out of the chemicals tank and hang it in a bucket with clean water.
Seal the chemicals tank with a cap and store safely.
5.3. Lance and gun
Uncouple the lance and put it away. Close the water supply. Roll up the high and low pressure hoses.
5.4. Water outlet
See chapter 1 - safety and 2.1.2.
5.5. Put away cleaner
Clean when necessary the water filter. Check if the cleaner is stored frost proof.
Furthermore, it is recommended to empty the water from cleaner and accessories, or to rinse with antifreeze.
Use the pull bar to move the cleaner, don't use the tube base support to move the cleaner!
5.6. Environmentally safe disposal of used fluids
No fluids (anti-scale product, oil, petrol, diesel, softener, ...) may be disposed randomly because of the environ-
ment! So make sure, if you are user, that the applicable local guidelines for environmentally friendly disposal of
these fluids (without soil pollution) are complied.
5.7. Transport
Pay attention at transport to the following:
Keeps the machine as much as possible horizontal while transporting, this prevents oil leaks from the pump.
Load the machine using a lift truck, hydraulic loading platform or a hoist.
Lash the machines (if necessary) solid fixed to the loading platform.
5.8. Transport at frost temperatures
Replace the water suction hose by a short piece hose and hang it with the end in the anti frost, so the machine
can suck in the anti frost product. Take the lance from the spray gun and operate the machine.
Spray until the anti frost flows from the spray gun.
The machine is now filled with anti frost, stop the machine.
Tip: by collecting the outgoing anti frost water, you can re-use the anti frost product again afterwards.
ECN-S REV 0