Safety Features; Listings And Certifications - Cinderella Classic Manuel De L'utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SAFETY FEATURES

1. The incineration process is inactive while the toilet lid is open. The heater element will not start until the seat and lid are
closed.
2. The hatch to the incineration chamber CANNOT remain open while the toilet is still hot (e.g. during cleaning).
This is only possible when the toilet has cooled down and the fan has stopped.
3. Should a ventilation problem arise and the internal temperature of the toilet increase to exceed 170 °F (80 °C),
incineration will be interrupted and a warning light displayed. This situation requires a manual reset to ensure the
ventilation issue is addressed before the toilet can be used again.
4. If the ash container is improperly positioned after emptying, incineration will not start and a warning light will be
displayed.
5. The air circulation system will continue to operate, even in the case of a power failure, until the internal temperature of the
toilet has returned to the normal range. The internal fan can continue to operate for up to five hours on battery power.
6. If the incineration chamber hatch mechanism gets jammed or is prevented from closing properly, incineration will not
start and an error message will be displayed.
7. The Cinderella Classic's onboard computer includes a "watchdog" system which monitors internal temperatures and other
indicators. If it detects anything unexpected, incineration will stop immediately and a warning message displayed.

LISTINGS AND CERTIFICATIONS

Cinderella Classic has been tested and approved by the consumer safety testing body UL, and meets the requirements of the
NSF Protocol for Electrical Incinerating Toilets NSF P-157 – Health and Sanitation.
SPECIAL-TYPE INCINERATOR
MH61230