Cinderella Classic Manuel De L'utilisateur page 15

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TROUBLESHOOTING
IMPORTANT NOTE:
How to reset the toilet system is described on the previous page.
Error
Ash container
must be emptied
Ash container
must be emptied,
toilet locked.
No power
Ventilation fan error
Hatch is jammed
/ bowl liner is
jammed
Ash container
in wrong position
Heating circuit
interrupted
Toilet lid opens.
Temperature
sensor is faulty,
shortcircuited or
broken.
Bad incineration or
smell
Yellow
Red
Flashing
Flashing
Lamp on
Lamp on
Flashing
Flashing
Flashing
Flashing
Flashing
Flashing
Flashing
Green
Sound What to Do
3 beeps
1
1
3 beeps
every 10 sec
1
Lamp off
2
Flashing
1
10 beeps
2
3
4
5
1
2
10 beeps
3
4
5
1
3 beeps
2
3
4
1
Continuous
2
3
4
1
1
Flashing
Continuous
2
3
4
1
2
English – User Manual Cinderella Classic
Remove and empty ash container.
Remove and empty ash container.
Plug in the toilet.
If problem persists, empty toilet and call for
service.
Check fan for obstructions.
Reset toilet.
Open and close toilet lid.
Start incineration.
If error persists, disconnect plug, empty toilet
and and call for service.
When toilet is hot: Reset toilet.
Open and close lid before pushing the Start
button.
If unsuccessful, reset toilet, insert liner, pour
in 3 cups of water and push the Start button.
If still unsuccessful,
wait until toilet has
cooled (fan stopped).
Try to remove paper/
liner manually.
If problem persists, empty toilet and call for
service.
Adjust the position of the ash container.
Check the stop pin on the ash container.
Visually check the condition of the magnet
on the ash container.
If problem persists, empty toilet and call for
service.
Unplug the toilet.
Wait 15 minutes.
Check temperature safety on right hand
side of toilet. Unscrew gray plug. Push on
fuse inside with finger, do not use any
sharp objects. If the fuse was triggered, you
will hear a click. If so, check inlet/outlet air.
If it was not the temperature safety, empty
toilet and call for service.
Close toilet lid.
Reset toilet.
Open and close lid.
Start incineration.
If error persists, empty toilet and call for
service.
Perform maintenance described on page
10–13. Check that the installation is cor-
rect as described in the installation manual.
If problem persists, empty toilet and call for
service.
15