Manufactured by:
RAIS A/S
Industrivej 20, DK-9900 Frederikshavn, Denmark
Model: Q-Tee II USA
Solid Fuel Room Heater
Date of manufacture
Model
Date of fabrication
Modéle
Clearances to combustible surfaces
Back wall
G
A
MINIMUM CLEARANCE
Rear Vent
With Pedestal With Pedestal No pedestal
A: SIDE WALL TO UNIT
14"/356mm
14"/356mm
B: BACK WALL TO UNIT
12"/305mm
12"/305mm
C: CORNER WALL TO UNIT
11"/280mm
N/A
D: CEILING HEIGHT
45"/1143mm 45"/1143mm
E: FRONT WALL / FURNISHING: 36"/915mm
36"/915mm
F: Back Wall to Pipe
15"/381mm
N/A
G: Side Wall to Pipe
22,5"/572mm 22,5"/572mm 23,5"/597mm
H: Corner Wall to Pipe
20"/508mm
N/A
Do not store wood logs or combustible materials underneath the room heater
FLOOR PROTECTION:
Floor protection requirements are dependent upon whether the optional High Socket
Base, Rais part number 838040590 is used;
Floor protection must be non-combustible material extending beneath the stove,
and to the front and sides from door opening and to the rear as indicated.
The floor protection needed on the floor when used WITHOUT the base is required to have
thermal protection with an R value of 3.19 Btu*in/Hrs*ft2*°F (equal to 0.46 w/mk in SI units).
with the base, the floor protection is not required to have thermal protection (R=0)
Replace glass with only Rais authorized dealer supplied ceramic glass
** Not Tested - NFPA Guidelines in USA, CAN/CSA B365-M91 in Canada
Tested to:
UL 1482-2011
ULC S627-00
For Use With Solid Wood Fuel Only
Month
Year
Mois
Année
Adjacent wall
C
H
Écartement minimum
15"/381mm
A: Mur latéral - Appareil
B: Mur arriére - Appareil
15"/381mm
C: Mur de coin - Appareil
13"/331mm
45"/1143mm
D: Plafond - Lappareil
36"/915mm
E: Distance meuble devant
F: Paroi arrière de cheminée
18"/458mm
G: Paroi arrière de cheminée 22,5"/572mm 22,5"/572mm 23,5"/597mm
22"/559mm
H: Coin mur pour cheminée
Ne pas stocker les journaux de bois ou des matériaux combustibles sous le radiateur de la chambre
Serial no.
N° de série
**Rear/Top vent option
Ceiling
**
See further floor protection requirements at bottom of this label.
Évent arrière
Avec piédestal Avec piédestal Sans piédestal
14"/356mm
14"/356mm
15"/381mm
12"/305mm
12"/305mm
15"/381mm
11"/280mm
N/A
13"/331mm
45"/1143mm 45"/1143mm
45"/1143mm
36"/915mm
36"/915mm
36"/915mm
15"/381mm
N/A
18"/458mm
20"/508mm
N/A
22"/559mm
U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply
with 2020 particulate emission standards using crib wood. 0.9
g/hr, Method 28R
This wood heater needs periodic inspection and repair for proper operation.
Consult the owner's manual for further information. It is against federal
regulations to operate this wood heater in a manner inconsistent with the
operating instructions in the owner's manual.
** Non testé - NFPA Guidelines au USA, CAN/CSA B365-M91 au Canada
La protection de sol doit être au moins de 3/8 inch matériel non combustible placé sous le foyer
s'étendant vers l'avant, les côtés les ouvertures et l'arriére comme induqué.
Report No. #0138WS016S
Made in Denmark
Fabriqué au Danemark
FLOOR PROTECTOR
2"
8"
8"
8"
Front
Floor protection for
Canada: 30" (76 cm)
from unit to front of floor protector.
Floor protector must be under the pipe and 2"