2.5. Positioning
The position of the chair compared to fixed obstacles must be such as to allow the easy passage for the use and main-
tenance; in particular, the minimum space to allow the passage of persons shall be equal to 650 mm (in accordance
with UNI EN 349:2008). The feet regulation can be done screwing or unscrewing them.
To prevent crushing of the whole body the minimum distance between the leg rest fully stretched and the back com-
pletely lowered and fixed obstacles must be equal to 500 mm.

2.6. Power supply

The system of power supply must have voltage and frequency equal to the rated voltage and frequency of the power
supply of the device and be appropriate to the installed capacity, as indicated on the identification plate of the chair.
Voltage
Frequency
Absorption
Transformer
Power
Supply
Fuse
Duty Cycle
IP protection
The power supply must be supplied to the unit by a line:
Protected against overcurrent by an automatic circuit breaker (circuit breaker) or fuses, properly sized; the ope-
rating current of the protections must be as low as possible taking into consideration the maximum absorption
of the device;
Equipped with a device sensitive to insulation failure (differential) with operating current low enough; this device
must be positioned downstream of the overcurrent protective device (or be integrated with it);
Having cables with section suitable for the power absorbed by the appliance.
The chair must also be connected to an external unipotential protection circuit (grounding)
adequate.
2.7. Connections
Plug the power cable into a suitable electric socket once you have connected to the chair (panel board): a beep sound
means the chair is correctly connected and it can work electrically. If there is incompatibility between the outlet and
the plug of the chair, ask qualified personnel to replace it with a suitable one.
HOLD THE PLUG, NOT THE CABLE WHILE DISCONNECTING THE EQUIPMENT.
6
100 / 110 / 230 V
50/60 Hz
0,70 A
120V - 25V
160 W
Single phase AC L+N
2,5 A rit. (230V) – 4A (110V) – 6,3A (100V)
2 min ON - 18 min OFF
IP 54
Control box class II
Handset control
Power cable
PANEL BOARD
Foot control