Before replacing the cylinder, make sure that the device is not near to any sources of fire or
other sources that could ignite.
It is essential to close the gas supply valve on the cylinder or regulator after each use.
If you smell any gas leakage, you must stop using of the device if it is running or if it is turned
off, do not start it, switch of the main gas valve on the gas cylinder and if still smell the gas,
call gas service and/or fire brigade. If you do not smell gas, investigate the appliance for any
leakages and rectify it before operation. If necessary contact the service center as well.
ATTENTION!!! It is recommended to periodically check the quality of connections for all gas hoses
including the rubber flexible hose (at least once a month or whenever the cylinder is replaced). If there
are visible cracks, damage or other signs of damage, the elements should be replaced with new ones
of the same length and equivalent quality.
OPERATION
The user choosing the gas garden fireplace receives a device equipped with a manual controller. Be-
fore operating the control module, read this manual. Proceedings contrary to the instructions may
result in damage to the gas control system components or the device itself, as well as to fire, property
damage or loss of health.
INSTRUCTIONS FOR MANUAL CONTROL MODULE
Firing up the appliance should follow the instructions below. The manual control system has been
designed to completely eliminate the need for its maintenance and any adjustment. Never attempt to
open or damage the valve or any of its other components in any way.
Firing up the appliance:
1. If you have just connected a gas cylinder to your device, bleed the control lines. Pressing the knob,
turn them counterclockwise until it stops and hold them for a maximum of 5 seconds (the gas will
flow to the control burner, but also to the main burner).
2. Continue pressing the knob and turn it back to the starting position and counterclockwise again
until it locks (this activates the pilot burner piezo igniter). Repeat as long as the control burner lights
up. (If this operation lasts longer than 30 seconds, wait 5 minutes and try again. If re-lighting does
not cause the control burner to fire, contact the service).
3. After the control burner has ignited, keep the knob pressed in this position for another 10 seconds
until the control burner has ignited
4. After ignition of the control burner, hold the knob in this position for 5 seconds until the thermo-
couple warms up, then release the knob counterclockwise further to the final position - nominal
furnace power (this will also start gas flow to the main burner) .
5. The adjustment is done by turning the knob from the final position (maximum power) to the firing
up position of the control burner (minimum power).
Turning off the appliance:
1. Turn the knob to the control torch firing position clockwise.
2. Press the knob lightly and continue turning it clockwise from the end position completely closing
the valve.
The next procedure of firing up the control burner may be repeated when the thermocouple of the
control burner has sufficiently cooled (the period until it cools down may vary depending on the type
of thermocouple used). After the device is completely turned off, re-lighting is possible after about 1
minute (time needed for the thermocouple to cool down).