Please note that noncombustible housing still must have at least one side wall open above the
burner pit. Every housing for appliance and its gas cylinder must have an easy access door for a gas
cylinder and ventilation holes at minimum of 0,1 m
The space indicated above is the minimum free space from flammable materials, unless this is
removed by another entry. Failure to observe the above clearances (free space) may result in a
fire or damage to health and property.
PLEASE NOTE: The device has been designed for installation in a special housing or tables provi-
ded by the manufacturer or in accordance with the safety requirements presented in this section
of the manual. The entire housing / table must meet the requirements of safety standards, inc-
luding slip tests. If the device is installed on a table or cabinet that does not meet the specified
requirements, the manufacturer is not responsible for any accidents or damages that may occur
to the customer, user or property.
It is absolutely forbidden to use the gas garden fireplace in an open space during ATMO-
SPHERIC precipitation.
STORING THE GAS GARDEN FIREPLACE OUTSIDE OF THE BUILDING IS ONLY PERMITTED
WHEN IT IS COVERED WITH THE RAIN COVER.
PLEASE NOTE THAT WHEN THE APPLIANCE IS INSTALLED, THE INSTALLATION MUST ENSURE
THE SUPPLY OF FRESH AIR UNDER THE FIREPLACE.
THE CYLINDER HAS TO BE PUTTED INTO THE SPECIFIED HOUSING WITH AN EASY ACCESS TO
THIS CYLINDER AFTER INSTALLATION AND A FRESH AIR SUPPLY.
IN ANY OTHER ACCIDENT, THE FIREPLACE SHOULD BE LOCATED IN A PLACE THAT IS PROTEC-
TED AGAINST FLOODING AND EFFECTS OF LOW TEMPERATURES.
THE APPLIANCE THAT IS NOT OPERATED SHOULD BE UNDERCURRENTLY CUT OFF THE GAS
SUPPLY. (GAS VALVE IN THE CLOSED POSITION), ALL SAFETY HANDLES SHOULD BE LOCKED,
AND THE DEVICE PROTECTED AGAINST FALLING. IF IT IS NOT POSSIBLE TO PROTECT THE AP-
PLIANCE AGAINST TIPING OR FALLING OUT AT THE TIME OF LEAVING IT WITHOUT ATTEN-
TION, THE GAS BOTTLE SHOULD DISCONNECT AND LEAVE IT IN A SAFE PLACE.
IN CASE OF VIOLENT WIND PRECAUTIONS MUST BE TAKEN AGAINST TILITING OF THE AP-
PLIANCE.

FIRST START

Before first use, make sure that all connections of individual system components have been made in
accordance with the instructions contained in the manual. Incorrect connection of the gas control
system may result in its damage.
During the first few ignitions a specific smell may be perceptible, persisting even for several hours after
using the device. This phenomenon is associated with the burning of paint. Animals may be particular-
ly sensitive to smells caused by burning off paint. To speed up the process, it is recommended to heat
the device to maximum flame for several hours.
.