6.7 LED groups enabling and
Fault connection

LED GROUPS ENABLING AND FAULT CONNECTION

Connectors
Terminals
J5
1 (RL1A), 2 (RL1B)
3 (A), 4 (B), 5 (COM)
Tab. 6

6.7.1 LED groups enabling

The product is equipped with two LED groups:
group A and group B. It is possible to manage the
switching on all, one or none of the LED groups, to
adapt the light intensity to the scene. To select the
units, wire the connector J5 as follows.
It is possible to enable the LED groups
with jumpers directly on the connector or
remotely by arranging suitable wiring.
• Enable groups A and B: no connection necessary.
J5
5
4 3
2
Fig. 19
• Enable group A only: install the connections as in
the diagram below.
J5
5
4 3
2
COM
A
Fig. 20
20
Description
Clean output contact
enabled by Fault
LED groups enabling
1
1
• Enabling group B only: install the connections as
in the diagram below.
J5
5
4 3
2
COM B
Fig. 21
• Turn off all LEDs: install the connections as in the
diagram below.
J5
5
4
3
2
COM B
A
Fig. 22
• Remote control of LED groups is possible. See the
example in the diagram below.
J5
5
COM
Fig. 23
Example of enabling / disabling both groups A and B.
1
1
4
3
2
1
B A