Labels; Installation; Preparation; Fixed Installation - Chicago Pneumatic CP 0020 Prescriptions De Sécurité Et Instructions Pour L'opérateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
Safety and operating instructions

Labels

Data plate
C
A
B
Machine type
A.
Maximum permitted compressed air pressure
B.
C.
Serial number
The warning symbol together with the book
D.
symbol means that the user must read the
safety and operating instructions before the
machine is used for the first time.
E.
The CE symbol means that the machine is
EC-approved. See the EC declaration which is
delivered with the machine for more
information. If the CE symbol is missing, it
means that the machine is not EC-approved.
Safety label
To avoid injury, before using or servicing tool, read
and understand separately provided safety
instructions.

Installation

Preparation

Always make sure that the pump stands stable on a
level surface.
Depending on the conditions at the worksite, the
pump can be installed in different ways.
If the exhaust-air outlet is located above the surface
of the liquid:
The pump can be started directly.
If the pump is submersed into the pumped medium:
10
NOTICE
underwater unless the exhaust air outlet is fitted with
a hose.

Fixed installation

D
E
The pump is primarily intended for use in temporary
(mobile) applications. If the pump is used in a fixed
installation, make sure that the connections between
pump and pipe are made with a flexible hose.

Hoses and connections

A.
B.
C.
Start the pump before submersing it into the
liquid.
If an exhaust hose is fitted to the exhaust-air
outlet, the pump can be submersed and then
started.
The pump must not be started or stopped
A
B
Compressed air source
Water separator (optional)
Max. 10 feet (3 meter) compressed air hose
between the water separator and the machine.
Check that you are using the correct
recommended operating pressure, 87 psig (6 bar).
The maximum permissible air pressure, 90 psig
(6,2 bar), must not be exceeded.
Blow any impurities out of the compressed air
hose before connecting it to the machine.
Choose a suitable hose size from the options
available and connect it to the water outlet on the
pump. For maximum flow with the CP pumps, a
3 in. (76 mm) hose is recommended.
Select the correct dimension and length for the
compressed air hose. For hose lengths up to 100
feet (30 meters), a hose with a minimum internal
diameter of
3
in. (19 mm) should be used. If the
4
hose length is between 100 and 330 feet (30 and
100 meters), a hose with a minimum internal
diameter of 1 in. (25 mm) should be used.
9800 1056 90c | Original instructions
CP 0020
C

Publicité

Table des Matières
loading

Table des Matières