Lenze EMZ2221IB Instructions De Montage page 39

Table des Matières

Publicité

Card module
Display
Text
E 3
Check drive
E 4
Repeat (T1 or T2)
E 5
Technology drive
needed
E 6
Drive not
supported
E 7
Prog. is defective
E 8
Program
incompatible
E F
Format card (T3)
EDKMZ2221IB DE/EN/FR 7.0
Troubleshooting and fault elimination
Cause
Cause
No program in basic device.
Basic device is not ready for
operation.
AIF access protection is activated
in the basic device (C0096/1
The data transmission has been
truncated or was faulty
PLC program contains technology
functions which cannot be
transferred to the existing basic
device.
Basic device is unknown or not
supported.
Stored data of the selected
program memory location are
faulty
The program is incompatible to
the basic device
Memory card is not formatted
Memory card is defective
l
Remedy
Remedy
Load program into basic device.
Reset TRIP in basic device and − if
necessary − disconnect mains.
Deactivate AIF access protection
¹
in the basic device (C0096/1 = 0)
0)
Restart data transmission
Servo PLC: use version "T".
ECS: use version ECSxA, ECSxS,
ECSxM, or ECSxP.
If required, contact Lenze service.
Use card module with supported
basic devices only (^ 25).
Choose other program memory
location
Press key T3 and write compatible
program on the memory card.
Press button T3 to format the
memory card.
During formatting the letter
indicated on the 7−segment
display.
Replace memory card