Extended functions
These functions can only be selected/set if the device is in programming mode
(button
).
• Predefined light values
• Predefined time setting
• Impulse mode activation
• Holiday mode
• Alarm mode
• Anti-creep protection ON/OFF
• Focus LED ON/OFF
• Electronic range adjustment
• Reset (resets to factory settings)
NB: The special impulse, holiday and alarm mode functions cannot be used at the same time.
The program activated most recently is active.
Button
Function
Opens programming mode
Indicated by flashing focus LED.
The set values are active once programming mode is closed
automatically activated after 5 minutes.
Closes programming mode
Test mode
During the test mode, the focus LED remains permanently on. Regardless
TEST
of the ambient brightness, if motion is detected, the blue mode LED will
switch ON for 1 second and OFF for 2 seconds. Press the
quit test mode.
Setting the light values (programming mode)
Day and night operation
The sun is starting to set (approx. 100 lux)
The sun is almost set (approx. 25 lux)
Night operation (approx. 2 lux)
Storing the current light value
Stores the current light value.
On-period (programming mode)
Adjustable from 15 seconds to 30 minutes.
Impulse mode (programming mode)
Impulse means that the device is activated for 1 second followed by a
break of 9 seconds in which no movement is detected. The red focus
LED flashes twice for each sequence. After the break, a new sequence is
triggered if motion is detected. This is suitable, for example, for controlling
automatic stairwell lights or a doorbell.
Continuous lighting ON/OFF
System can be switched ON or OFF, independently of motion or ambient
brightness, for 12 hours max.
or are
To disable this function, press the
programming mode. (Resets factory settings).
Operating continuous lighting ON/OFF
Continuous light mode OFF disabled – Every time the
pressed, the light switches ON for 12 hours. Continuous light OFF enabled
– Pressing the
the
button to
RESET
360° anti-creep protection ON/OFF (programming mode)
Deactivates the downward-facing 360° sensor to avoid the device
switching on accidentally. Press the
creep protection.
NB: To prevent tampering, the continuous lighting OFF function is disabled in
the factory settings. Activation is only possible during the self-test. Switch the
power supply on and press the
button during the self-test. The
continuous light OFF function is now enabled.
button when the device is in
RESET
button once switches the light ON for 12 hours. If the
button is pressed again, the light will switch OFF for 12 hours. Press
button again to switch the light OFF – ON – OFF – ON.
NB: Pressing the
button deactivates the special impulse mode, alarm
mode and holiday mode functions. After the 12-hour „continuous ON/OFF"
period has expired, or if the
button is pressed, the detector will switch
to automatic mode.
button again to reactivate anti-