7+/8- 12V dc power supply for the photocells or external radiocontrol.
9/10 12V max 10 W external blinker
11/12 M1 (11 brown 12 blue)
13/14 M2 (13 brown 14 blue)
17/16 N.C. photocell, connect if the contact is not used (optional)
17/15 N.O. Start contact for key or push-button
18/19 External antenna (optional)
To connect one motor only:
Purchasing a single wing gate kit Ref. 412... the programmer is
already preset.
In case a double wing gate kit 812... is installed, if you want to operate
one motor only, contact the nearer assistance centre for the special
programming.

3.2 Special connections

Important, only for references:
HC412/400/00 and 812/400/00 professional automations.
Programmer version CTR35/S
You can:
1. Connect an electric lock.
2. Connect an output for the garden light.
3. Open only a wing to allow the pedestrian passage.
How to proceed:
1. Carry out all the connections, see paragraph 3.1 and possibly pho-
tocells, see paragraph 3.4
2. Connect terminals:
1-2 to a low voltage relay which is connected to the garden lights
3-4 to a 12 V ac electric lock which will be activated at each start
5-6 to a key which activates the pedestrian passage only.
Caution, pressing once the key connected to N.O. (normally open)
terminals 5-6 the wing corresponding to the first motor M1 will be
opened.
The wing will open and will remain opened for some seconds
necessary to let the person pass then it will close automatically.
3.3 Setting: Programmer functions
The software has already been programmed with the step-to-step
function. Therefore it is possible to perform the opening and closing by
simply pressing the transmitter T1 key.
A. To select the "AUTOMATIC CLOSING" temporised function:
1.Press P3 key until the LED 2 fixed light is on.
2.Release the key
3.Wait for the desired pause time
4.Then press P3 key again
The programming is concluded. Now, by pressing the gate transmitter
key the gate will close after the pause time you set. During the ope-
ning it won't be possible to perform other operations while during clo-
Fig. 14
sing an pulse will make it reopen.
Important: the constant pulse will keep the gate open.
B. To go back to the "STEP-TO-STEP" function:
1.Press the P3 key. The Led 2 will light up
2.Keep it pressed until the Led 2 goes off
You are back to the step-to-step function.
To set the motor thrust:
The CTR35 card is programmed with a standard thrust.
It is however possible to carry out a self-setting of the needed power
(ex. in case of strong wind) following these instructions:
1.Open the two gate wings manually using the emergency unlocking
Fig. 3.
Important: wings have to be completely open.
Locking the wings.
2.Press P2 key until the LED 2 and the blinker light up
3.Release the P2 key
The programmer will perform a series of measurement operations for
approx. 20 seconds then the Led will turn off and the system will be
set for your gate.