For Higher Safety; Emercency Control; Compliance To Norms; Actuators Assembly To K Plate - Ducati HC 800 Manuel De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37
812/00 corretto
26-09-2001 9:25
Pagina 30
The system is provided with a crushing-proof electronic safety device
controlled by microprocessor. Check the perfect alignment of the gate
hinge pivots for a correct adjustment.

1.5 For higher safety

We advise to install one or two pair of photocells. They shall provide
for the reopening of the wings in case an object obstructs their way.
We also advise to comply with norms concerning automation in force
in the various countries.
1.6 Emergency control
In case the system fails, the gate can be manually opened.
Insert the triangular key inside the triangular plug placed over the
motors, then turn counter-clockwise till the stop. Motors shall unlock.
The inverse operation restores the gate automation.

1.7 Compliance to norms

The equipment is in compliance with EEC directives: EEC 89/392
EN61000-3-2 EN61000-3-3. EN55014 ETS 300 683 ENV 50141. 1-
ETS 300-220 CEPT T/R 01-04. Class II equipment.
EEC 72/23 EN60335/1, EN60529/II, EN60034.
TUV GS APPROVAL No. B 96 05 26270001.
2.0 Actuators assembly to "K" plate
Assemble the adjustable "K" plate and fix it to the wall. This operation
is extremely important as it shall determine the following parameters:
1. Gate opening speed
2. Actuator thrust strength
Fundamental elements to make this choice are the following:
1. The gate size (weight/length)
2. Pillar size
Fig.16
You will find a series of sizes to determine the positioning of K plate
with respect to the gate "V" rotation axis (hinge pivot). Fig.F6
- F7 300mm STROKE ACTUATORS
- F8 400mm STROKE ACTUATORS
For gate whose length is longer than cm 150, consider "B" measures
higher than 10 cm.
Fig. F3
Some standard advised measures are (for 300 mm stroke actuators):
Gates not exceeding 150 cm
A=10 cm / B= 10 cm
Gates exceeding 150 cm
A= 14 cm / B= 12 cm
- Remind the higher is "B" measure, the slower the gate will open.
Caution:
maximum thrust strength allowed: 15 N
In order to be sure not to exceed 15 Kg of thrust strength, do not use
measures shown in the blackened boxes of Fig. 7. In case it were
necessary to use those measures, it is compulsory to install a double
pair of safety photocells. (Ref. 7012)

2.1 Front support assembly

Fig. 4
After the "K" plate fixation, install the actuator the pivot. Fig.1 pos. H.
Then provide for the "STOP" installations on the ground.
- Open the gate wing till the desired position is reached
30