english
extension cord could result in risk of fire,
electric shock or electrocution.
• When operating a charger outdoors, always
provide a dry location and use an extension
cord suitable for outdoor use. Use of a cord
suitable for outdoor use reduces the risk of
electric shock.
• Do not block the ventilation slots on the
charger. The ventilation slots are located
on the top and sides of the charger. Place
the charger in a position away from any heat
source.
• Do not operate charger with damaged cord
or plug — have them replaced immediately.
• Do not operate charger if it has received
a sharp blow, been dropped or otherwise
damaged in any way. Take it to an authorised
service centre.
• Do not disassemble the charger; take it to
an authorised service centre when service or
repair is required. Incorrect reassembly may
result in a risk of electric shock, electrocution or
fire.
• In case of damaged power supply cord the
supply cord must be replaced immediately by
the manufacturer, its service agent or similar
qualified person to prevent any hazard.
• Disconnect the charger from the outlet
before attempting any cleaning. This will
reduce the risk of electric shock. Removing
the battery pack will not reduce this risk.
• NEVER attempt to connect 2 chargers together.
• The charger is designed to operate on
standard 230 V household electrical power.
Do not attempt to use it on any other
voltage. This does not apply to the vehicular
charger.
SAVE THESE INSTRUCTIONS
Chargers
The DCB105, DCB107, DCB112, DCB113 and
DCB115 chargers accept 10.8V, 14.4V and 18V
Li-Ion XR (DCB140, DCB141, DCB142, DCB143,
DCB144, DCB145, DCB180, DCB181, DCB182,
DCB183, DCB183B, DCB184, DCB184B and
DCB185) battery packs.
D
WALT chargers require no adjustment and are
e
designed to be as easy as possible to operate.
Charging Procedure (Fig. 2)
1. Plug the charger into an appropriate outlet
before inserting battery pack.
36
2. Insert the battery pack (g) into the charger.
The red (charging) light will blink continuously
indicating that the charging process has started.
3. The completion of charge will be indicated by
the red light remaining ON continuously. The
pack is fully charged and may be used at this
time or left in the charger.
NOTE: To ensure maximum performance and life
of lithium-ion batteries, charge the battery pack fully
before first use.

Charging Process

Refer to the table below for the charge status of the
battery pack.
Charge indicators: DCB105
charging
fully charged
hot/cold pack delay
replace battery pack
Charge indicators: DCB107, DCB112, DCB113, DCB115
charging
fully charged
hot/cold pack delay*
*DCB107, DCB112, DCB113, DCB115: The
red light will continue to blink, but a yellow
indicator light will be illuminated during this
operation. Once the battery has reached an
appropriate temperature, the yellow light will turn
off and the charger will resume the charging
procedure.
The compatible charger(s) will not charge a faulty
battery pack. The charger will indicate faulty battery
by refusing to light or by displaying problem pack or
charger blink pattern.
NOTE: This could also mean a problem with a
charger.
If the charger indicates a problem, take the charger
and battery pack to be tested at an authorised
service centre.
HOT/COLD PACK DELAY
When the charger detects a battery that is too hot
or too cold, it automatically starts a Hot/Cold Pack
Delay, suspending charging until the battery has
reached an appropriate temperature. The charger
then automatically switches to the pack charging
mode. This feature ensures maximum battery life.