■ Remove the air distribution ring using the SATA extraction tool [8-1].
■ Check sealing surface [8-2] for soiling, clean if necessary.
Mount the air distribution ring
■ Insert air distribution ring. The pin [8-3] of the air distribution ring must
be aligned accordingly.
■ Press the air distribution ring in evenly.
■ Mount nozzle set (see chapter 9.1).
After installation, adjust the material flow according to chapter 8.2.
9.3. Replace paint needle seal
This must be replaced when material leaks from the self-adjusting paint
needle packing.
Dismantle paint needle seal
■ Dismantle nozzle set (see chapter 9.1).
■ Screw seal retainer [9-1] out of the gun body.
■ Remove seal [9-2] and spring [9-3].
Mount paint needle seal
■ Insert seal [9-2] and spring [9-3].
■ Screw seal retainer [9-1] into the gun body.
■ Mount nozzle set (see chapter 9.1).
After installation, adjust the material flow according to chapter 8.2.
9.4. Replace air piston, air piston spring and air micrometer
Risk of injuries from air micrometer coming loose.
When the locking screw is not screwed tight, the air micrometer can
shoot uncontrolled out of the spray gun.
→ Check that the locking screw of the air micrometer fits firmly and
tighten if necessary.
Replacement is necessary if
air escapes at the air cap or air micrometer without actuating the trigger
guard.
Dismantle air piston, air piston spring and air micrometer
■ Screw locking screw [10-2] out of gun body.
■ Pull the air micrometer [10-5] out of the gun body.
■ Remove air piston [10-3] with air piston spring [10-4].