SATA minijet 1000 K Mode D'emploi page 133

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 189
Operating instructions SATAminijet 1000 K/H RP/HVLP
Notice!
The most precise way to adjust the gun inner pressure is with SATA
adam 2 [3-1].
Notice!
If the gun input pressure does not reach the necessary level, increase
the pressure in the compressed air circuit.
Too much input pressure results in high trigger forces.
■ Pull trigger guard [1-10] right back.
■ Adjust the gun input pressure to one of the following settings [3-1],
[3-2], [3-3] to [3-4]. Note the maximum gun inlet pressure (see chap-
ter 7).
■ Bring the trigger guard to the starting position.
Adjust the material flow
Notice!
Wear at the fluid tip and paint needle is lowest when the material flow
control is wide open. Select fluid tip size according to the material and
working speed.
Fully variable adjustment of the material flow and thus the needle stroke
is possible with the adjusting screw as shown in Figs. [4-1], [4-2], [4-3]
and [4-4].
■ Loosen counter nut [1-3].
■ Pull trigger guard [1-10] right back.
■ Adjust material flow at the adjusting screw [1-2].
■ Tighten counter nut by hand.
For SATAminijet 1000 K
■ Pull trigger guard [1-10] right back.
■ Adjust material supply pressure for example at pressure vessel.
Adjustment of spray pattern
Fully variable adjustment of the spray fan pattern is possible using the
round/flat fan control [1-1] to achieve a round fan.
■ Adjust the spray fan pattern by regulating the round and flat fan control
[1-1].
■ Turn to the right [5-2] – for a round fan
■ Turn to the left [5-1] – for a flat fan
EN
133

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Minijet 1000 h

Table des Matières