The connection between the actuator and the mounting bracket is a quick hook connection with no fixing screws required (patented) and
allows the actuator to turn in response to the chain stroke even on low windows.

5. TECHNICAL DATA

Model
Force exerted by thrust and traction (F
Strokes (S
)
V
Power supply voltage (U
)
N
Rated absorbed current (I
)
N
Power absorbed at nominal load (P
No load speed
Duration of no load stroke
Electrical insulation
Type of service (D
)
R
Operating temperature
Protection index for electrical devices
Soft-stop function
Relax function
Adjustment of connection to window frame
Parallel powering of two or more motors
Synchronised function
Holding nominal force (it can vary according to the chosen
brackets)
Stroke-end at opening
Stroke-end at closing
Signalling 'window open/window closed'
Type and length of power cable
Dimensions
Weight

6. CONSTRUCTION AND REGULATORY REFERENCES

INTENDED USE. The actuator is designed and built to move awning windows, bottom-hung windows, parallel-opening
windows, light domes, dormer windows and skylights. Its use is specifically intended for ventilation and natural air conditioning
of rooms (230V~ version), while the 24V
control units; any other use is strongly discouraged, with the supplier of the entire system in any case retaining sole liability.
The actuator is manufactured in accordance with the Directives and following Regulations listed in the attached Declaration of
Incorporation and Conformity
Electrical connections must conform to regulations in force for the design and set up of electrical equipment.
To ensure efficient separation from the grid, an approved type of bipolar "dead-man" switch should be used. An omnipolar general
power switch with minimum distance of 3 mm between contacts should be installed upstream of the control line.
The actuator is individually packaged in a cardboard container and each pack contains:
• 110-230V~ 50/60Hz or 24V
• Instructions manual.
• Installation accessories (if requested).
Brackets are not included in the parcel and have to be requested separately in function of the applications.
IMPORTANT. The Syncro version of the actuator is packed in a cardboard box with two units and is shipped already tested.
However, the RESET procedure must still be performed (see section 12.2).

7. ID PLATE AND MARKING DATA

Actuators have CE marking and comply with the Standards listed in the Declaration of Conformity. They also come with a Declaration of
Incorporation, due to their classification by the Machinery Directive as "partly completed machines". Both declarations are included in the
final pages of this manual.
The plate data is displayed on an adhesive label placed on the outside of the casing, which must remain intact and visible. The main
information it displays includes: manufacturer's address, product name - model number, technical characteristics, production date and
serial number.
In the event of a complaint, please indicate the serial number (SN) displayed on the label.
An explanation of the symbols used on the label to abbreviate the technical characteristics is given in the table in the chapter on
"TECHNICAL DATA".

8. ACTUATOR DIMENSIONS

The actuator's main dimensions are provided in the table below and relate to application on bottom-hung and top-hung windows.
However, for perfect application on windows, users are advised to request drawings and work out the best solution.
)
N
)
N
Data provided in these illustrations is not binding and is subject to change even without prior notice.
version is intended for smoke and heat exhaust systems controlled by appropriate
.
electrical actuator.
VARIA TUBE
VARIA TUBE
230V
230V SYNCRO
350N (see force chart)
300 (100,175) – 600 (400,500) – 800 (600,700) – 1000 (800,900)
110-230V~ 50/60Hz
0,33A – 0,22A (230V)
27-29W
Stroke 300 / 600 / 800 / 1000 = 28 / 54 / 72 / 90 s
Class II
Position self-determining
No
Yes (Syncro) max
8
Electronic by dip-switch setting
At absorption of power
Yes, with specific device to request at order
H05VV-F – 2m
FRR/2
– 2,5 m
34,6x37 L468/624/727/824
0,9 / 1,4 / 1,8 / 2,2 kg
23
VARIA TUBE
24V
24V
0,950A
23W
11 / 9,5 mm/s
Class III (Selv)
2 cycles
- 10 + 70 °C
IP32
Yes
Yes
Yes (max 10)
No
Yes (Syncro) max
1800 N
S-FG4GA/2- 2m
34,6x37 L408/564/667/764
0,8 / 1,3 / 1,7 / 2,1 kg
VARIA TUBE
24V SYNCRO
8

Publicité