The actuator is produced by the factory with the stroke-end for return set at around +1 cm (out by 1
cm). This allows the actuator to be assembled without electrical energy powering movement and
means that the window remains closed after assembly. The joint between actuator and support
brackets is quick, requires no fixing screws (patent) and allows the actuator to rotate to follow the track
of the chain even on shorter windows.

4. MANUFACTURE AND APPLICABLE STANDARDS OR REGULATIONS

INTENDED USE. The chain operated series VARIA SLIM BASE actuator has been
designed and manufactured to open and close top hung windows, bottom hung
windows, dormer windows, light domes and skylights. It has been specifically designed
for ventilation and climate control; any other use is strongly discouraged, with the
supplier of the entire system in any case retaining sole liability.
The actuator is manufactured in accordance with the Directives and following
Regulations listed in the attached Declaration of Incorporation and Conformity
Electrical connections must conform to regulations in force for the design and set up of
electrical equipment.
To ensure efficient separation from the grid, an approved type of bipolar "dead-man"
switch should be used. An omnipolar general power switch with minimum distance of 3
mm between contacts should be installed upstream of the control line.
The actuator is packaged in cardboard boxing and each package contains:
• Electrical actuator with either 110÷230V~ (a.c.) 50/60Hz or 24V
connected to the machine.
• Drilling template.
• Standard support brackets (A).
• Bracket for bottom hung window (C).
• Bracket for top hung window (D).
• Instructions manual.

5. TECHNICAL DATA

Model
Force exerted by thrust and traction (F
Strokes (S
)
V
Power supply voltage (U
Rated absorbed current (I
Power absorbed at nominal load (P
No load speed
Duration of no load stroke (360 mm)
Electrical insulation
Type of service (D
Operating temperature
Protection index for electrical devices
Adjustment of connection to window frame
Parallel powering of two or more motors
Synchronised function
Holding nominal force (it can vary according to
the chosen brackets)
Stroke-end at opening
Stroke-end at closing
Length of power cable
)
N
)
N
)
N
)
R
VARIA SLIM BASE
)
N
110-230V~ 50/60Hz
0,42A - 0,21A
~ 23-20W
15 mm/s
Class II
2 cycles
Automatic definition of position
26
(d.c.) with electrical cable directly
VARIA SLIM BASE
230V
250N
240, 360 mm
24 s
Class III (Selv)
- 5 + 65 ºC
IP30
YES (max 30 actuators)
Not foreseen
1500N
At absorption of power
At absorption of power
1 m
.
24V
24V
0,78A
~ 19W
13,3 mm/s
27 s
5 cycles