48 | English
Measure the ceiling height H as for a length measurement. The measured value is dis-
played in the top measured-value line. The laser remains switched on.
Then measure the length L
calculated and displayed in the result line (e). The last measured
1.291
m
H
value for length can be found in the bottom measured value line (d).
0.0°
2.583
m
L
The laser remains switched on.
2.583 m
L
2
3.336 m
Now measure the length L
ured value displayed in the measured value line (d) is added to the
length L
. The sum of the two lengths (displayed in the middle measured value line (d)) is
1
multiplied by the saved height H. The total area value is displayed in the result line (e).
You can measure any number of lengths L
plied by the height H. The requirement for a correct area calculation is that the first
measured length (for example the ceiling height H) is identical for all sub-areas.
Stake out function (see figure I)
The stake out function repeatedly measures a defined length (distance). These lengths
can be transferred to a surface, for example to enable material to be cut into pieces of
equal lengths or to install stud walls in a drywall construction. The minimum adjustable
length is 0.1 m and the maximum length is 50 m.
Note: The distance from the marking is shown in the display in the stake out function.
The reference is not the edge of the measuring tool.
Select the stake out function .
Use the button (6) [+] or the button (3) [–] to set the required length.
Begin the stake out function by pressing the measuring button (5) [ ] and slowly move
away from the starting point.
The measuring tool continuously measures the distance to the start-
ing point. The defined length and the current measured value are
thereby displayed. The lower or upper arrow displays the shortest
14x
0.200m
distance to the next or last marking.
2.800
m
The left factor specifies how many times the defined length has
14 x
already been reached. A green measured value indicates that a length
14.44x
0.200m
has been reached for marking purposes.
2.887
m
A blue measured value indicates the actual value when the reference
value is outside the display.
1 609 92A 4ZJ | (14.10.2020)
of the first wall. The area is automatically
1
of the second wall. The individual meas-
2
, which will be automatically added and multi-
x
Bosch Power Tools