Messages
Code Error description
E01
Excessive tempe-
rature
E02
Mains overvoltage
E03
Overcurrent
E06
Overvoltage
E07
EEProm checksum
error
E08
Wire feed
E09
Voltage-measuring
E13
Temp. sensor error
E14
Supply voltage
E15
Power measuring
E16
Supply voltage
motor and main
contactor
E17
Peripherie overload/
short circuit
E18
Error configuration
Tab. 8:
Messages
01.10
Note
The equipment has been overhea-
ted
Mains input voltage too high
Output current is too high / Perma-
nent short circuit
Output voltage too high
Setting data faulty or missing
Too high power intake from wire
feed motor (Motor Over-Current)
Voltage measuring system defective Service verständigen
Thermal sensor not ready for ope-
ration
internal supply voltage too low
(18V~ / 24V-)
Fault at power measuring
Internal supply voltage is too little
(42V~ / 60V-)
Short circuit in torch or hose packa-
ge, gas valve or feed line, wire run
key or line
Faulty or wrong pc-board,
wrong software system played
Rectification
Allow the system to cool
down in standby, check
the ventilation system
Check mains voltage
Service verständigen
Inform Service
Switch the equipment
off and on again
Blow down torch pac-
kage with pressured air
and check pressure on
wire feed rolls.
Inform Service
Check mains voltages
Service verständigen
Check power supply
voltage
Test alt. exchange the
connected torch
Inform Service