Réglages D'usine - ACV Compact Condens 170 Mode D'emploi

Table des Matières

Publicité

GUIDE DE L'INSTALLATEUR
RÉGLAGES D'USINE
1
ADVANCED CH SETTINGS
2
ADVANCED DHW SETTINGS
3
SYSTEM SETTINGS
4
DIAGNOSTICS
5
USER SETTINGS
6
Cascade
7
RESTORE FACTORY SETTINGS
TECHNICIAN MENU
1
Maximum power
1
CH power set
2
Minimum power
Absolute max. temperature
1
2
CH temperatures
CH maximum setpoint
2
CH minimum setpoint
3
4
CH setpoint hysteresis
Outside temp for max CH
1
Outside temp for min CH
2
3
OTC parameters
3
Outside temp for CH off
OTC setpoint table
4
5
OTC curve
4
CH pump settings
1
Post pump time
CH anticycling timer
5
6
CH request type
Maximum power
1
1
DHW power
Minimum power
2
1
Storage temperature setpoint
2
DHW temperatures
Boiler temperature setpoint
2
DHW setpoint hysteresis
3
3
DHW pump settings
1
DHW post time
1 DHW priority Status
4
DHW priority
2 DHW priority TimeOut
5
DHW request type
Ignition power
1
2
Delay siphon check
3
Number of boiler pumps
1
Boiler parameters
PWM pump speed Max
4
PWM pump speed min
5
6
Antilegionella
Modbus parameters
7
8 3 Way valve travel ti me
1
Select language
Select units
2
2
User interface settings
3
Set date
4
Set time
Service information
1
3
Service settings
2
Service due date
Boiler information
1
Overview lockout history
2
Lockout history
3
Manual test
1 CH temperature/OTC set
0
Heating
2
ECO setpoint reduction
3 Scheduler set
1
DHW setpoint (NTC sensor)
DHW setpoint (Thermostated)
1
2
Domestic hot water
2
ECO setpoint reduction
3 Scheduler set
1
CH holiday setpoint
3
Holiday
1 DHW holiday setpoint (Thermostated)
DHW holiday setpoint (Sensor)
2
1
Cascade switch delay
Cascade min power
2
3 Burner power (default value x= 170,210,250,290 boiler specifiic) kW
4
Boiler for DHW
1
Cascade set
PI loop period
5
6
Burner water flow delay
Different boiler size
7
Cascade pump speed mx.
8
9 Cascade pump speed min
Cascade Role : see Cascade auto detecftion
1
2 System temperature
2
Cascade info
3 Number of boilers on
4 Modulation level
3
Cascade auto detect : press OK to start detecting role boiler in cascade chain
Compact Condens : A1003043 - 664Y7200 • C
default
100
0
90
85
20
5
-10
18
OFF
10
3
RT+SP/OT
onlyOTC|RT
100
0
80
60
6
1
Enabled
Enabled
Off
Swicth
Switch
10
3
check syphon is not emptied by new value
2 pump
Pump 3-w-valve
100
40
Enabled
Disabled
Adress
Baudrate
180
English
English | Italian | Spanish
Celsius
Fahrenheit
24 Hours
24 hours
Set telelphone number
Set service date
Real time boiler status
Status boiler at time of lock/block
See chimney sweeper
1
CH set point
85
2
Outside temperature for CH off
off
50
1
Enable/disable on board scheduler
Enabled
Disabled
2
Scheduler set
Set time scheduler (Time/On/ECO/OFF)
60
80
20
1
Enable/disable on board scheduler
Enabled
Disabled
Set time scheduler (Time/On/ECO/OFF)
2
Scheduler set
20
80
60
30
20
x
0
5
30
Disabled
Disabled
100
40
Standalone
Standalone
Actual temperature Cascade system sensor
Actual number of burners /boilers on in cascade
Actual cascade modulation level
Standalone
Standalone
Reset to factory/check settings
Min
Max
After factory reset
0
100
100
0
100
0
80
20
90
Higher than 90 not allowed
75
20
Abs. max CH temp
40
20
70
2
10
3
-10
-34
10
18
15
25
7
30
OFF
OTC table
OTC curve
1
30
5
0
15
01-Vdc % | SP
RT+SP/OT
100
0
100
0
0
100
35
85
80
60
35
65
3
2
10
OFF
180
30
Enabled
Disabled
1
60
Off
Sensor
Switch
0
20
Higher than 20 not allowed
0
20
10
2 pump
2 pump
100
1
100
30
1
100
Enabled
Disabled
Frame
1
255
10
German | Russian
Celsius
Set date
12 hours
75
20
90/abs max CH temp
7
25
off
0
50
Enabled
35
65
60
80
35
85
0
50
Enabled
20
90/Abs max CH temp
35
85
10
65
0
255
0
100
0
2550
1
6
0
5
0
15
0
255
30
Disabled
Enabled
100
15
100
15
100
30
Master | Slave
Master | Slave
EN
FR
NL
ES
IT
DE
PL
RU
fr
17