Troubleshooting - Dometic MAGICWATCH MWE 820 Instructions De Montage Et De Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
MWE820, 860, 890
12

Troubleshooting

The device indicates no function.
The voltage supply cable (black/blue and brown wires) is not connected or is
incorrectly connected.
➤ Check the connections.
The plugs for the sensors are not connected or are not properly plugged into the
control electronics.
➤ Check the plugs, and make sure they lock into place.
A long tone sounds (approx. 3 seconds) after switching on the ignition
One or more sensors are defective or no longer connected to the control electron-
ics. The loudspeaker indicates the faulty sensor by the number of beeps after the
long beep: for example three beeps for sensor 3.
➤ Check the plugs and make sure they lock into place.
➤ Replace the defective sensor(s).
A
NOTICE!
The system no longer works reliably if one or more sensors are faulty.
Device indicates obstacles incorrectly.
False alarms may have the following causes:
• For example dirt or frost on the sensors
➤ Clean the sensors.
• The sensors were incorrectly installed.
➤ Adjust the direction or height of the sensors (fig. 3).
• The sensors have contact with the chassis.
➤ Disconnect the sensors from the chassis.
Objects on the vehicle (e. g. spare wheel) lead to false alarms.
➤ Set the system so that fixed objects are no longer displayed (see chapter "Setting
the system" on page 9).
EN
Troubleshooting
13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Magicwatch mwe 860Magicwatch mwe 890

Table des Matières