W 650
Measuring the Viscosity
1. Stir the coating material thoroughly before measuring.
2. Dip the viscosity test cup (Fig. 2. a or b) completely into the coating material.
3. Hold the test cup up and measure the time in seconds until the liquid empties out.
(Fig. 2)
This time is called "Runout Time in Seconds".
Spray material
Thinner-soluble primers
Thinner-soluble varnishes
Water-soluble primers
Water-soluble varnishes
Wood preservatives, strippers, oils
Disinfectants, plant protectants
Automobile spray paint
1
Air cap
2
Nozzle
3
Union nut
4
Spray gun
5
Trigger guard
6
Material volume adjustment
7
ON / OFF switch
Max. Viscosity:
Voltage:
Power consumption:
Atomisation power:
Double insulation:
Sound pressure level:
Oscillation level:
Air hose length:
Weight:

Viscosity Table

Large
Test Cup
25-40
15-40
25-40
20-35
20-35

Description (Fig.1)

8
Air hose
9
Carrying belt
10
Air filter
11
Air screen
12
Mains lead
13
Spray gun holder
14
Container
Technical Data
40 DIN-s
230 - 240 V ~
350 W
95 W
80 dB (A)
< 2,5 m/s²
1,8 m
3,3 kg
Runout Time in Seconds