strength may be used, which could result in
skin inflammation.
On broken skin. The electrode pads could
encourage infection.
On the front of the neck. This could cause
the
airway
breathing problems. May cause sudden
drop
in
blood
response).
Over the eyes. May affect eyesight or cause
headaches.
Across the front of the head. Effect on
patients who have had strokes or seizures
is not known. May affect your sense of
balance. The effects of stimulation on the
brain are unknown.
ELECTRODE PADS CAUTION:
Caution: Do not ignore any allergic reaction to
the electrode pads: If a skin irritation develops,
stop using the device, as this type of electrodes
may not be suitable for you. Alternative
electrode pads specially made for sensitive skin
are available (see E-696-SS).
Caution: Do not use this device with leads or
electrode pads other than those recommended
by the manufacturer. Performance may vary
from specification. Electrodes with smaller
surface area may cause tissue irritation.
Note: Electrode pads supplied have
no measurable latex content.
TO
KEEP
YOUR
WORKING
ORDER,
FOLLOWING ADDITIONAL CAUTIONS:
Caution: Do not immerse your device in water
or place it close to excessive heat such as a
fireplace or radiant heater or sources of high
to
close,
giving
pressure
(vasovagal
DEVICE
IN
GOOD
OBSERVE
THE
humidity such as a nebulizer or kettle as this
may cause it to cease to operate correctly.
Caution: Keep the device away from sunlight,
as long-term exposure to sunlight may affect
the rubber causing it to become less elastic and
crack.
Caution: Keep the device away from lint and
dust, as long-term exposure to lint or dust may
affect the sockets or cause the battery
connector to develop a bad contact.
Caution: Temperature & Relative Humidity of
storage: -25°C to +70°C, up to 93% R.H.
Temperature
transportation: -25°C to +70°C, up to 93% R.H.
Caution: Do not attempt to open or modify the
unit. This may affect the safe operation of the
unit and will invalidate the warranty.
Note: There are no known side
effects to use and long-term use is not
harmful. However, the device works
your muscles and unaccustomed amounts of
exercise may produce muscle ache. If this
happens, simply reduce the strength of the
machine or allow your muscles to rest until the
aching disappears.
4.
INFORMATION
THE
SETTINGS
Each programme has its own combination of
Frequency and Pulse Width settings which
allow for different muscle groups to be
exercised and toned through the electrode
pads.
Frequency (measured in Hz - pulses per
second)
8
&
Relative
Humidity