Nice UST1-FU Instructions D'installation Et D'utilisation page 29

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
WARNINGS
• All of the technical characteristics indicated refer to a temperature of 20°C (± 5°C).
• Nice reserves the right to introduce all modifications to the product it deems necessary at any time, however keeping the functions and intended use
unaltered.
DESCRIPTION
Voltage power supply:
Connecting the motor via inverter:
Power at rest:
Ambient temperature:
Control voltage:
Protection rating:
Dimensions:
HDF – INVERTER TABLE
MOTOR
INVERTER
0.37 KW
0.75 KW - INVERTER
0.55 KW
0.75 KW - INVERTER
0.75 KW
1.5 KW – INVERTER
1.1 KW
2.2 KW – INVERTER
1.5 KW
2.2 KW –INVERTER
2.2 KW
3 KW – INVERTER
The control unit is totally assembled and wired, ready for connection.
The control unit is to be kept inside its packaging during transport and storage, if any, to prevent damage.
For disposal, it is necessary to separate
− metals
− plastic elements
− electrical components
− lubricants.
We specifically clarify that we neither carry out tests nor are we willing to approve any spare parts and/or accessories not
supplied by us.
The assembly and/or use of products of this type could jeopardise gearmotor features pre-defined at the construction level,
which can reflect on safety.
NICE declines all responsibility and disclaims any warranty whatsoever for damages, if any, caused by using non-original
spare parts and/or accessories.
Defects that cannot be remedied internally are to be eliminated only by the door manufacturer or another specialised
company, from which it is possible to also request any necessary spare parts.
TECHNICAL DATA - FEATURES
MOTOR VOLTAGE
3 Phases – 230V
3 Phases – 230V
3 Phases – 230V
3 Phases – 230V
3 Phases – 230V
3 Phases – 400V
TRANSPORT / STORAGE / DISPOSAL
TECHNICAL ASSISTANCE / SPARE PARTS / ACCESSORIES
UST1-FU
DATA
1 x 230V AC 50Hz (10A protection)
3 x 400V AC 50Hz (16A protection)
see the table below
< 4VA
from -10°C to +50°C
Additional delayed 0.8A fuse
IP 54 (IP 65 optional)
255 x 180 x 120mm (HxWxD)
English – 13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ust1-fu3

Table des Matières