* In caso di cavi
separati, per azionamenti
con finecorsa elettronico.
KEY
J1
U-bolt 8.2 kΩ I Opto
J2
U-bolt 8.2 kΩ I Opto
J3
coupling for plug modules (10-pole)
J4
DW switch mech. test enabling (lower door pos.)
J6
change-over contact with zero potential (brake)
J11
motor
J15
STOP button (opening contact)
J16
OPENING button (closing contact)
J17
impulse button (closing contact)
J18
CLOSING button (closing contact)
J26
CLOSING limit switch (opening contact)
J27
OPENING limit switch (opening contact)
J28
additional CLOSING limit switch (preliminary limit switch)
J29
safety circuit (opening contact)
J31
photoelectric barrier passage (opening contact)
12 – English
UST1-FU WIRING DIAGRAM
2
Pink
Green
*Grey
Brown
White
Yellow
Grey
*Green
X11
Three-phase
INVERTER
PROCESSOR
X2
INV.
Single-phase INVERTER
INVERTER
connection
J32
closing edge safety system
J38
coupling for radio receiver - Nice OXI
X1
network coupling terminal
X2
motor coupling terminal
X3
coupling terminal for change-over contact with zero
potential
X4
coupling terminal of control devices
X5
coupling terminal of passage photoelectric barrier
X6
coupling terminal for lower edge bar
X7
coupling terminal of limit switch
X8
coupling for brake relay
X9
coupling for key switch
X10
coupling for triple switch
X11
coupling terminal for inverter
X12
connection of service LED