Error Messages - Roco multiMAUS Manuel

Masquer les pouces Voir aussi pour multiMAUS:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Error Messages

ERR 1:
Not compatible for programming.
ERR 2:
No confirmation was received from the decoder when programming / reading.
Check whether the connection to the decoder is faulty due to dirt on the tracks or wheel contacts. Re-
place the locomotive on the track.
Check whether there is a capacitor somewhere in the track system.
ERR 3:
A short circuit has occurred whilst programming / reading.
Check whether the locomotive is placed correctly on the track and make sure the wiring is not faulty.
The locomotive may be standing on a polarized frog (the turnout setting however does not match the
route of the locomotive).
The decoder may not be connected properly on a converted locomotive.
ERR 4:
Not possible in "POM" mode.
This error occurs if the multiMAUS is changed over to "POM" mode (page 49) when you are intending
to program CV1 (locomotive address). Program CV1 on a separate section of programming track in "CV
mode" (see page 49).
ERR 5:
Programming mode is active.
ERR 6:
Not available because track voltage is switched off (occurs in "POM" mode).
ERR 7:
The library is empty (menu "LOCO" – "DELETE").
ERR 8:
The library is full (e.g. when entering a new locomotive).
You can save a maximum of 64 locomotives in the library. Control the locomotive using locomotive ad-
dress mode or use an additional multiMAUS.
ERR 9:
The locomotive was not found (menu "LOCO" – "SEARCH").
The locomotive address has not been created in the library.
ERR 10:
A locomotive with the same address already exists (when entering a new locomotive in the locomotive
library).
ERR 11:
The locomotive address is outside the valid value range.
You are using a Lokmaus 2, for instance, as the master and it only supports 99 locomotive addresses.
ERR 12:
X-PressNet is not compatible with X-Bus.
Only X-PressNet versions 3.0 and above are compatible with the multiMAUS.
ERR 13:
No X-PressNet master was found.
There is a problem with the device connected to the master output. Unplug the device and reconnect it.
If this does not solve the problem, check the X-Bus address.
ERR 14:
The calibration values are invalid.
The controller needs to be recalibrated. See page 52, 3.5.6.
ERR 90 and above:
Your multiMAUS is unfortunately in need of service by the ROCO service department.
59

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

10810Multimaus 10810

Table des Matières