Output data

Switching principle
Rated operating voltage U
as per IEC 60947-1
e
operating voltage range as per IEC 60947-1
operating voltage range as per UL 508
Load current at 20°C (see chapter 9)
Rated operating current I
as per IEC 60947-1
e
AC-51 as per IEC 60947-4-3
AC-53a as per IEC 60947-4-2
as per UL 508 (see chapter 9)
Normal switching power as per UL 508
Full Load (power factor = 0.4)
Full Load (power factor = 0.8)
Leakage current (input, output)
Residual voltage at I
e
Surge current
Input protective circuit
Short circuit current rating SCCR as per
UL 508a (under preparation)
Reply output
Contact type
Contact material, in new condition
When used as
Max. switching voltage
Min. switching voltage
Max. continuous load current Io
Min. switching current
Max. interrupting rating *, ohmic load 24V DC / 250V AC
Measurement technology
Two-phase current measurement, Range
Symmetry monitoring
Amount I
> I
=> (I
- I
max
nenn
max
min
Amount I
< I
=> (I
- I
max
nenn
max
min
Response time
Phase failure monitoring, I (L1), I(L3) typ.
Amount (angle (L1, L3))
Response time
Blocking protection, I (L1) oder I(L3)
Response time
Trigger characteristic (see chapter 9) as per IEC 60947
Cooling-down time

Operating elements

operating voltage indicator
Device and process error display
Activation display
Button
Potentiometer for nominal motor current setting
* Other available on request.
Revision 1, Stand 05.2012
in ref. to 9. Trigger characteristic curve
/ I
)
max
/ I
)
nenn
Max. 0.6A
Max. 2.4A
Safety output module with bypass,
three-phase electrically isolated shutdown
500V AC (50 / 60Hz)
42 – 500V AC
0.075 – 0.6A
0.18 – 2.4A
0.6A
2.4A
0.6A
2.4A
0.6A
2.4A
0.3kW (0.4HP)
0.9kW (1.2HP)
0.5kW (0.6HP)
1.7kW (2.2HP)
0mA
< 300mV
< 400mV
100A (t = 10ms)
Varistors, fuses
With fuse class J (30A), suitable for use in circuits, that do not
supply more than 100kA
symmetrical current, max. 500V
eff
Single contact, 1PDT contact
Ag alloy, hard gold-plated
Signal contact
30V AC / 36V DC
100mV
50mA
1mA
1.2W / –
0.07 – 0.6A
0.18 – 2.4A
≥ 33% / ≥ 67%
≥ 33% / ≥ 67%
≥ 33% / ≥ 67%
≥ 33% / ≥ 67%
2min. / 1.8s
> 75mA
> 150mA
170 – 190
< 1.8s
Class 10A
20min.
LED PWR (green)
LED Err (red)
LED L (yellow) / LED R (yellow)
Error acknowledgement
240°
English.
Max. 9A
1.2 – 9A
9A
6.5A
6.5A
2.3kW (3.0HP)
4.6kW (6.1HP)
< 500mV
Power contact
250V AC / DC
12V AC / DC
6A
10mA
140W / 1500VA
1.5 – 9A
≥ 33% / ≥ 67%
≥ 33% / ≥ 67%
> 1200mA
> 45A
2s