3.7
When Using In Non-automation
Installations And With Jandy Variable
Speed Pump
As stated in Section 3.3, the power pack must be
interconnected with the pool pump motor power source
to ensure that the chlorinator only operates when the
pool pump is running. The Jandy TruClear chlorination
system with Firmware Revision F or later, can monitor
the state of the Jandy Variable Speed Pump so that the
TruClear does not operate if the Jandy Variable Speed
Pump is not running.
The power pack comes equipped with a slide out RS485
connector. The RS485 connector is used to connect the
Jandy TruClear chlorination system to a new or existing
Jandy Variable Speed Pump.
1.
Loosen DO NOT REMOVE the two screws
securing the RS485 connector bracket in place. It is
not required to remove the entire front cover plate.
2.
Slide out the 4 pin RS485 connection terminal.
3.
From the Jandy Variable Speed Pump run a parallel
(to the existing controller) RS485 cable to the 4 pin
RS485 connection terminal.
4.
Unscrew cable fi tting nut, pass RS485 wires
through and resecure the nut.
5.
Pass wires through center slot on bracket.
6.
Use a fl at head screwdriver to install the wires from
the Jandy Variable Speed Pump. Match the colors
to the wires already installed from the power pack.
7.
Once connection has been
made, the User Interface
(UI) should display "Standby #".
8.
Once proper communication is confi rmed, reinstall
the RS485 connector bracket into the power pack
body.
9.
If proper communication is not established, begin
with step 3 and retrace the above steps.
10. If communication is still not established, please call
technical support at 800-822-7933.
Jandy
TruClear
Chlorine Generating System
®
3.8
The National Electrical Code
States) or the Canadian Electrical Code (CEC in Canada)
requires pool equipment to be bonded to each other.
Check your local codes to determine if the NEC or CEC
and/or other local installation codes are enforced by the
Authority Having Jurisdiction (AHJ in the United States)
or the local competent authorities in Canada. A solid,
copper 8.37 mm
NEC and 13.3 mm² (6AWG) per the CEC, for bonding
the power pack to a permanent bonding connection that
is acceptable to the local AHJ or the local competent
authorities in Canada.
Refer to your locally enforced codes for the acceptable
bonding wire gauge. Attach the bonding point located
on the bottom of the chassis backplate to a common
bonding point. Do not use the power pack as the
common bonding point. Each piece of non-related pool
equipment requiring a ground should also be bonded to
the common, approved bonding point. There should be
one bonding connection to the power pack. In Canada,
the Canadian Electrical Code (CEC) dictates that the
bonding conductor be, minimum 13.3 mm
National Electrical Code® (NEC®) requires bonding
of the Pool Water. Where none of the bonded pool
equipment, structures, or parts are in direct connection
with the pool water; the pool water shall be in
direct contact with an approved corrosion-resistant
conductive surface that exposes not less than 5800
mm² (9 in²) of the surface area to the pool water at all
times. The conductive surface shall be located where
it is not exposed to physical damage or dislodgement
during usual pool activities, and it shall be bonded in
accordance with the bonding requirements of NEC
Article 680. Refer to your locally enforced codes for any
additional bonding requirements.
3.9
If the chlorinator is used with an in-fl oor cleaning
system, it must be installed in a separate dedicated return
line or damage to the chlorinator will occur.
ENGLISH
NOTE
Figure 8.
|
Installation & Operation Manual

Bonding

(NEC
®
(8 AWG) wire is recommended, per the
2
Split Return Plumbing Instructions:
For Infloor Cleaning Systems
Do not install the chlorinator on in-floor systems that
do not have a dedicated pool return as shown in
Figure 8.
POOL RETURN
CELL
New Pool Plumbing for In-Floor Systems
in the United
®
(6 AWG).
2
FROM
THE
PUMP
TO INFLOOR
CLEANER

Publicité