Wires must
Violet
be connected
together when
White
wiring for
240VAC
Red
Red
L2
Figure 4.
Wiring with a 240 VAC Filter Pump
1.
Wire power pack to pool pump power source
using 3.3 mm
(12 AWG) insulated wire and
2
conduit. Wire the power pack to the LOAD side
of the fi lter pump or the LOAD side of the pool
pump timer relay so that the chlorinator can
only come on when the pool pump comes on
(see Figure 4 for 240 VAC and Figure 5 for 120 VAC).
2.
Remove the electrical mounting plate that feeds the
power cable to the power pack.
3.
Feed the power cable through the mounting plate.
4.
Connect the conduit to the mounting plate.
5.
Make the wire connections. Note: The green
wire should be connected to the ground point.
(see Figure 4 for 240 VAC and Figure 5 for 120 VAC).
6.
Place all of the wire connections and cables inside
the power pack and secure the electrical mounting
plate tightly.
WARNING
Select field conductor size appropriately, taking into
consideration length of circuit and in accordance with
applicable installation codes. The ground conductor
must be minimum 12 AWG.
7.
Plug the cell into the Power Pack.
Jandy
TruClear
Chlorine Generating System
®
Black
Green
Green
Black
L1
Ground
Figure 5.
3.6
The power pack comes equipped with a slide out RS485
connector. The RS485 connector is used to connect the
Jandy TruClear chlorination system to a new or existing
AquaLink
1.
Loosen DO NOT REMOVE the two screws
securing the RS485 connector bracket in place. It is
not required to remove the entire front cover plate.
2.
Slide out the 4 pin RS485 connection terminal.
3.
From an open auxiliary on your automation system
run the RS485 cable to the 4 pin RS485 connection
terminal.
|
Installation & Operation Manual
White
Red
White
Neutral
Wiring with a 120 VAC Filter Pump

Install RS485 for Jandy Automation

Automation System.
®
Violet
Black
Green
Green
Black
Load 1
Ground

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Truclear11ku

Table des Matières